US Bridges

Cbe Service RD EB over RTE 907H RTE 907H

Fair

Bronx County, New York · JCT I95+BRONX River Pkwy · Structure no. 000000001076680

Built
1951
74 years old
Condition
Fair
inspected August 2023
Type
Frame
Concrete Continuous
Length
114 ft
2 main spans
Daily traffic
4,338
2019 count
Owner
State
State Highway Agency

About this bridge

Cbe Service RD EB over RTE 907H RTE 907H is a concrete continuous frame carrying Cbe Service RD EB over RTE 907H RTE 907H in Bronx County, New York. It was built in 1951, so it is 74 years old, older than the New York average of 53 years.

The most recent inspection reported to the Federal Highway Administration rates it in fair condition with a lowest component rating of 6 out of 9. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

It carries about 4,338 vehicles a day, roughly 9% of them trucks, projected to reach 8,512 by 2041. The structure is 114 ft (34.7 m) long and 57 ft wide. If it were closed, the detour would be 0.6 mi (1 km).

CarriesCbe Service RD EB
CrossesRTE 907H RTE 907H
LocationJCT I95+BRONX River Pkwy
RouteCity Street 0
Coordinates40.83597, -73.8738
Functional classUrban Collector

Condition and inspection

Fair

The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

ComponentRatingMeaning
Deck6 SatisfactoryStructural elements show some minor deterioration.
Superstructure6 SatisfactoryStructural elements show some minor deterioration.
Substructure7 GoodSome minor problems.
Last inspectionAugust 2023
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourBridge not over waterway
Structural evaluation6: Equal to present minimum criteria
Deck geometry2: Basically intolerable, requiring high priority of replacement
Approach roadway alignment8: Equal to present desirable criteria
Operating rating99 US tons
Inventory rating61 US tons

Structure

Structure typeFrame
MaterialConcrete Continuous
DeckNot applicable
Main spans2
Design loadHS 20
Structure length114 ft (34.7 m)
Longest span61 ft (18.5 m)
Deck width57 ft (17.4 m)
Roadway width40 ft (12.2 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic4,338 (2019)
Projected traffic8,512 by 2041
Trucks9%
Lanes on structure4
Traffic directionOne-way traffic
CarriesHighway and pedestrian
CrossesHighway
Detour if closed0.6 mi (1 km)
TollOn a free road
National Highway SystemNo

Ownership and planned work

OwnerState Highway Agency
Maintained byState Highway Agency
Historic statusHistorical significance not determinable at this time
Work proposedWidening with deck rehabilitation or replacement
Estimated improvement cost$8.1 million (2024 estimate)
NavigationNot applicable (no waterway)

Frequently asked questions

When was Cbe Service RD EB over RTE 907H RTE 907H built?

It was built in 1951, making it 74 years old in 2025.

What condition is Cbe Service RD EB over RTE 907H RTE 907H in?

The National Bridge Inventory rates it in fair condition. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. The last reported inspection was in August 2023.

How much traffic does Cbe Service RD EB over RTE 907H RTE 907H carry?

About 4,338 vehicles per day (2019 count), of which roughly 9% are trucks.

How long is Cbe Service RD EB over RTE 907H RTE 907H?

The structure is 114 ft (34.7 m) long with a longest span of 61 ft (18.5 m) and a deck 57 ft wide.

Who owns Cbe Service RD EB over RTE 907H RTE 907H?

It is owned by the State Highway Agency.