US Bridges

Pgbt WB over Midway RD

Good

Denton County, Texas · 0.85 MI W of Dallas Tlwy · Structure no. 180610296404545

Built
2001
24 years old
Condition
Good
inspected November 2023
Type
Stringer/Multi-beam or Girder
Prestressed Concrete
Length
235 ft
3 main spans
Daily traffic
8,000
2014 count
Owner
Toll Authority
Local Toll Authority

About this bridge

Pgbt WB over Midway RD is a prestressed concrete stringer/multi-beam or girder carrying Pgbt WB over Midway RD in Denton County, Texas. It was built in 2001, so it is 24 years old, younger than the Texas average of 44.4 years.

The most recent inspection reported to the Federal Highway Administration rates it in good condition with a lowest component rating of 7 out of 9. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

It carries about 8,000 vehicles a day, roughly 7% of them trucks, projected to reach 50,800 by 2034. The structure is 235 ft (71.6 m) long and 70 ft wide.

CarriesPgbt WB
CrossesMidway RD
Location0.85 MI W of Dallas Tlwy
StateTexas
Coordinates33.01289, -96.84363
Functional classUrban Principal Arterial - Other Freeway or Expressway

Condition and inspection

Good

All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

ComponentRatingMeaning
Deck7 GoodSome minor problems.
Superstructure8 Very GoodNo problems noted.
Substructure7 GoodSome minor problems.
Last inspectionNovember 2023
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourBridge not over waterway
Structural evaluation7: Better than present minimum criteria
Deck geometry6: Equal to present minimum criteria
Approach roadway alignment8: Equal to present desirable criteria
Operating rating60 US tons
Inventory rating36 US tons

Structure

MaterialPrestressed Concrete
DeckConcrete, precast panels
Main spans3
Design loadHS 20
Structure length235 ft (71.6 m)
Longest span115 ft (35.1 m)
Deck width70 ft (21.3 m)
Roadway width67 ft (20.5 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic8,000 (2014)
Projected traffic50,800 by 2034
Trucks7%
Lanes on structure4
Traffic directionOne-way traffic
CarriesHighway
CrossesHighway
Detour if closed—
TollOn a toll road
National Highway SystemYes

Ownership and planned work

OwnerLocal Toll Authority
Maintained byLocal Toll Authority
Historic statusNot eligible for the National Register of Historic Places
Work proposedNone recorded
Estimated improvement cost—
NavigationNot applicable (no waterway)

Frequently asked questions

When was Pgbt WB over Midway RD built?

It was built in 2001, making it 24 years old in 2025.

What condition is Pgbt WB over Midway RD in?

The National Bridge Inventory rates it in good condition. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted. The last reported inspection was in November 2023.

How much traffic does Pgbt WB over Midway RD carry?

About 8,000 vehicles per day (2014 count), of which roughly 7% are trucks.

How long is Pgbt WB over Midway RD?

The structure is 235 ft (71.6 m) long with a longest span of 115 ft (35.1 m) and a deck 70 ft wide.

Who owns Pgbt WB over Midway RD?

It is owned by the Local Toll Authority.