US Bridges

Cohancy ST over RTE 907D RTE 907D

Poor

Queens County, New York · 1.8 MI W I678 & Belt Pkwy · Structure no. 000000002231570

Built
1941
84 years old
Condition
Poor
inspected April 2024
Type
Frame
Concrete Continuous
Length
113 ft
2 main spans
Daily traffic
7,616
2017 count
Owner
City
City or Municipal Highway Agency

About this bridge

Cohancy ST over RTE 907D RTE 907D is a concrete continuous frame carrying Cohancy ST over RTE 907D RTE 907D in Queens County, New York. It was built in 1941, so it is 84 years old, older than the New York average of 53 years.

The most recent inspection reported to the Federal Highway Administration rates it in poor condition with a lowest component rating of 4 out of 9. The lowest-rated primary component is rated 4 or below, indicating advanced deterioration. Poor does not mean unsafe; such bridges are inspected more often and may carry load restrictions.

It carries about 7,616 vehicles a day, roughly 4% of them trucks, projected to reach 9,251 by 2041. The structure is 113 ft (34.4 m) long and 57 ft wide. If it were closed, the detour would be 0.6 mi (1 km).

CarriesCohancy ST
CrossesRTE 907D RTE 907D
Location1.8 MI W I678 & Belt Pkwy
RouteCity Street 0
Coordinates40.66646, -73.83485
Functional classUrban Minor Arterial

Condition and inspection

Poor

The lowest-rated primary component is rated 4 or below, indicating advanced deterioration. Poor does not mean unsafe; such bridges are inspected more often and may carry load restrictions.

ComponentRatingMeaning
Deck6 SatisfactoryStructural elements show some minor deterioration.
Superstructure4 PoorAdvanced section loss, deterioration, spalling or scour.
Substructure5 FairAll primary structural elements are sound but may have minor section loss, cracking, spalling or scour.
Last inspectionApril 2024
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourBridge not over waterway
Structural evaluation4: Meets minimum tolerable limits to be left in place as is
Deck geometry4: Meets minimum tolerable limits to be left in place as is
Approach roadway alignment8: Equal to present desirable criteria
Operating rating60.6 US tons
Inventory rating24.6 US tons

Structure

Structure typeFrame
MaterialConcrete Continuous
DeckNot applicable
Main spans2
Design loadH 20
Structure length113 ft (34.4 m)
Longest span57 ft (17.3 m)
Deck width57 ft (17.4 m)
Roadway width34 ft (10.4 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic7,616 (2017)
Projected traffic9,251 by 2041
Trucks4%
Lanes on structure2
Traffic directionTwo-way traffic
CarriesHighway and pedestrian
CrossesHighway
Detour if closed0.6 mi (1 km)
TollOn a free road
National Highway SystemNo

Ownership and planned work

OwnerCity or Municipal Highway Agency
Maintained byCity or Municipal Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedWidening with deck rehabilitation or replacement
Estimated improvement cost$7.2 million (2024 estimate)
NavigationNot applicable (no waterway)

Frequently asked questions

When was Cohancy ST over RTE 907D RTE 907D built?

It was built in 1941, making it 84 years old in 2025.

What condition is Cohancy ST over RTE 907D RTE 907D in?

The National Bridge Inventory rates it in poor condition. The lowest-rated primary component is rated 4 or below, indicating advanced deterioration. Poor does not mean unsafe; such bridges are inspected more often and may carry load restrictions. The last reported inspection was in April 2024.

How much traffic does Cohancy ST over RTE 907D RTE 907D carry?

About 7,616 vehicles per day (2017 count), of which roughly 4% are trucks.

How long is Cohancy ST over RTE 907D RTE 907D?

The structure is 113 ft (34.4 m) long with a longest span of 57 ft (17.3 m) and a deck 57 ft wide.

Who owns Cohancy ST over RTE 907D RTE 907D?

It is owned by the City or Municipal Highway Agency.