Division ST over Division Creek
FairPosted for loadJones County, Iowa · 000000000 · Structure no. 000000000000310
- Built
- 1900
- 125 years old, rebuilt 2012
- Condition
- Fair
- inspected November 2024
- Type
- Stringer/Multi-beam or Girder
- Wood or Timber
- Length
- 25 ft
- 1 main span
- Daily traffic
- 555
- 2022 count
- Owner
- City
- City or Municipal Highway Agency
About this bridge
Division ST over Division Creek is a wood or timber stringer/multi-beam or girder carrying Division ST over Division Creek in Jones County, Iowa. It was built in 1900 and reconstructed in 2012, so it is 125 years old, older than the Iowa average of 45.5 years.
The most recent inspection reported to the Federal Highway Administration rates it in fair condition with a lowest component rating of 5 out of 9. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. Its operating status is: posted for load restriction.
It carries about 555 vehicles a day, projected to reach 555 by 2044. The structure is 25 ft (7.6 m) long and 19 ft wide.
Location
Open in Google MapsCondition and inspection
The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.
| Component | Rating | Meaning |
|---|---|---|
| Deck | 5 Fair | All primary structural elements are sound but may have minor section loss, cracking, spalling or scour. |
| Superstructure | 6 Satisfactory | Structural elements show some minor deterioration. |
| Substructure | 5 Fair | All primary structural elements are sound but may have minor section loss, cracking, spalling or scour. |
| Channel and channel protection | 5 Fair | All primary structural elements are sound but may have minor section loss, cracking, spalling or scour. |
Structure
Traffic and service
Ownership and planned work
Frequently asked questions
When was Division ST over Division Creek built?
It was built in 1900, making it 125 years old in 2025. It was reconstructed in 2012.
What condition is Division ST over Division Creek in?
The National Bridge Inventory rates it in fair condition. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. The last reported inspection was in November 2024.
How much traffic does Division ST over Division Creek carry?
About 555 vehicles per day (2022 count).
How long is Division ST over Division Creek?
The structure is 25 ft (7.6 m) long with a longest span of 23 ft (7 m) and a deck 19 ft wide.
Who owns Division ST over Division Creek?
It is owned by the City or Municipal Highway Agency.