US Bridges

Fulton Street over I-75-3 I-75R-1 MRT-1 Cs

Good

Fulton County, Georgia · In Atlanta · Structure no. 000000012106540

Built
1988
37 years old
Condition
Good
inspected July 2023
Type
Box Beam or Girders - Multiple
Prestressed Concrete Continuous
Length
622 ft
5 main spans
Daily traffic
860
2024 count
Owner
State
State Highway Agency

About this bridge

Fulton Street over I-75-3 I-75R-1 MRT-1 Cs is a prestressed concrete continuous box beam or girders - multiple carrying Fulton Street over I-75-3 I-75R-1 MRT-1 Cs in Fulton County, Georgia. It was built in 1988, so it is 37 years old, younger than the Georgia average of 47.5 years.

The most recent inspection reported to the Federal Highway Administration rates it in good condition with a lowest component rating of 7 out of 9. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

It carries about 860 vehicles a day, roughly 2% of them trucks, projected to reach 1,530 by 2030. The structure is 622 ft (189.6 m) long and 88 ft wide. If it were closed, the detour would be 1.9 mi (3 km).

CarriesFulton Street
CrossesI-75-3 I-75R-1 MRT-1 Cs
LocationIn Atlanta
RouteCity Street 9167
StateGeorgia
Coordinates33.74194, -84.39164
Functional classUrban Local

Condition and inspection

Good

All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

ComponentRatingMeaning
Deck7 GoodSome minor problems.
Superstructure7 GoodSome minor problems.
Substructure7 GoodSome minor problems.
Last inspectionJuly 2023
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourBridge not over waterway
Structural evaluation7: Better than present minimum criteria
Deck geometry5: Somewhat better than minimum adequacy to tolerate being left in place as is
Approach roadway alignment8: Equal to present desirable criteria
Operating rating61 US tons
Inventory rating35.9 US tons

Structure

MaterialPrestressed Concrete Continuous
DeckConcrete, precast panels
Main spans5
Design loadHS 20 + Mod
Structure length622 ft (189.6 m)
Longest span164 ft (50 m)
Deck width88 ft (26.9 m)
Roadway width66 ft (20.1 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic860 (2024)
Projected traffic1,530 by 2030
Trucks2%
Lanes on structure5
Traffic directionTwo-way traffic
CarriesHighway and pedestrian
CrossesHighway
Detour if closed1.9 mi (3 km)
TollOn a free road
National Highway SystemYes
Strategic Highway NetworkInterstate STRAHNET route

Ownership and planned work

OwnerState Highway Agency
Maintained byState Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedNone recorded
Estimated improvement cost$6.6 million
NavigationNot applicable (no waterway)

Frequently asked questions

When was Fulton Street over I-75-3 I-75R-1 MRT-1 Cs built?

It was built in 1988, making it 37 years old in 2025.

What condition is Fulton Street over I-75-3 I-75R-1 MRT-1 Cs in?

The National Bridge Inventory rates it in good condition. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted. The last reported inspection was in July 2023.

How much traffic does Fulton Street over I-75-3 I-75R-1 MRT-1 Cs carry?

About 860 vehicles per day (2024 count), of which roughly 2% are trucks.

How long is Fulton Street over I-75-3 I-75R-1 MRT-1 Cs?

The structure is 622 ft (189.6 m) long with a longest span of 164 ft (50 m) and a deck 88 ft wide.

Who owns Fulton Street over I-75-3 I-75R-1 MRT-1 Cs?

It is owned by the State Highway Agency.