C2002 over S. Br. Saxtons River

Good

Windham County, Vermont · 0.1 MI to JCT W CL3 TH46 · Structure no. 101306001713061

Built
1998
27 years old
Condition
Good
inspected October 2024
Type
Stringer/Multi-beam or Girder
Steel
Length
106 ft
1 main span
Daily traffic
545
2019 count
Owner
Town / Township
Town or Township Highway Agency

About this bridge

C2002 over S. Br. Saxtons River is a steel stringer/multi-beam or girder carrying C2002 over S. Br. Saxtons River in Windham County, Vermont. It was built in 1998, so it is 27 years old, younger than the Vermont average of 60.8 years.

The most recent inspection reported to the Federal Highway Administration rates it in good condition with a lowest component rating of 7 out of 9. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

It carries about 545 vehicles a day, roughly 5% of them trucks, projected to reach 573 by 2029. The structure is 106 ft (32.3 m) long and 29 ft wide. If it were closed, the detour would be 16.8 mi (27 km).

CarriesC2002
CrossesS. Br. Saxtons River
Location0.1 MI to JCT W CL3 TH46
StateVermont
Coordinates43.15256, -72.62258
Functional classRural Minor Collector

Condition and inspection

Good

All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

ComponentRatingMeaning
Deck8 Very GoodNo problems noted.
Superstructure8 Very GoodNo problems noted.
Substructure7 GoodSome minor problems.
Channel and channel protection8 Very GoodNo problems noted.
Last inspectionOctober 2024
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourFoundations stable; scour above top of footing
Structural evaluation7: Better than present minimum criteria
Deck geometry5: Somewhat better than minimum adequacy to tolerate being left in place as is
Waterway adequacy8: Equal to present desirable criteria
Approach roadway alignment8: Equal to present desirable criteria
Operating rating99 US tons
Inventory rating70 US tons

Structure

MaterialSteel
DeckConcrete, cast-in-place
Main spans1
Design loadHS 25 or greater
Structure length106 ft (32.3 m)
Longest span102 ft (31.1 m)
Deck width29 ft (8.7 m)
Roadway width27 ft (8.1 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic545 (2019)
Projected traffic573 by 2029
Trucks5%
Lanes on structure2
Traffic directionTwo-way traffic
CarriesHighway
CrossesWaterway
Detour if closed16.8 mi (27 km)
TollOn a free road
National Highway SystemNo

Ownership and planned work

OwnerTown or Township Highway Agency
Maintained byTown or Township Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedNone recorded
Estimated improvement cost—
NavigationNo navigation control on waterway

Frequently asked questions

When was C2002 over S. Br. Saxtons River built?

It was built in 1998, making it 27 years old in 2025.

What condition is C2002 over S. Br. Saxtons River in?

The National Bridge Inventory rates it in good condition. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted. The last reported inspection was in October 2024.

How much traffic does C2002 over S. Br. Saxtons River carry?

About 545 vehicles per day (2019 count), of which roughly 5% are trucks.

How long is C2002 over S. Br. Saxtons River?

The structure is 106 ft (32.3 m) long with a longest span of 102 ft (31.1 m) and a deck 29 ft wide.

Who owns C2002 over S. Br. Saxtons River?

It is owned by the Town or Township Highway Agency.