US Bridges

C2002 over Roaring Brook

Good

Orleans County, Vermont · 0.05 MI to JCT W C3 TH43 · Structure no. 101002000810021

Built
2015
10 years old
Condition
Good
inspected September 2024
Type
Tee Beam
Prestressed Concrete
Length
48 ft
1 main span
Daily traffic
920
2019 count
Owner
Town / Township
Town or Township Highway Agency

About this bridge

C2002 over Roaring Brook is a prestressed concrete tee beam carrying C2002 over Roaring Brook in Orleans County, Vermont. It was built in 2015, so it is 10 years old, younger than the Vermont average of 60.8 years.

The most recent inspection reported to the Federal Highway Administration rates it in good condition with a lowest component rating of 8 out of 9. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

It carries about 920 vehicles a day, roughly 2% of them trucks, projected to reach 966 by 2029. The structure is 48 ft (14.6 m) long and 29 ft wide. If it were closed, the detour would be 8.1 mi (13 km).

CarriesC2002
CrossesRoaring Brook
Location0.05 MI to JCT W C3 TH43
StateVermont
Coordinates44.73891, -72.21396
Functional classRural Minor Collector

Condition and inspection

Good

All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

ComponentRatingMeaning
Deck8 Very GoodNo problems noted.
Superstructure8 Very GoodNo problems noted.
Substructure8 Very GoodNo problems noted.
Channel and channel protection8 Very GoodNo problems noted.
Last inspectionSeptember 2024
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourFoundations stable; scour above top of footing
Structural evaluation8: Equal to present desirable criteria
Deck geometry5: Somewhat better than minimum adequacy to tolerate being left in place as is
Waterway adequacy6: Equal to present minimum criteria
Approach roadway alignment8: Equal to present desirable criteria
Operating rating64 US tons
Inventory rating49.1 US tons

Structure

Structure typeTee Beam
MaterialPrestressed Concrete
DeckConcrete, precast panels
Main spans1
Design loadHL 93
Structure length48 ft (14.6 m)
Longest span45 ft (13.7 m)
Deck width29 ft (8.8 m)
Roadway width26 ft (7.9 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic920 (2019)
Projected traffic966 by 2029
Trucks2%
Lanes on structure2
Traffic directionTwo-way traffic
CarriesHighway
CrossesWaterway
Detour if closed8.1 mi (13 km)
TollOn a free road
National Highway SystemNo

Ownership and planned work

OwnerTown or Township Highway Agency
Maintained byTown or Township Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedNone recorded
Estimated improvement cost—
NavigationNo navigation control on waterway

Frequently asked questions

When was C2002 over Roaring Brook built?

It was built in 2015, making it 10 years old in 2025.

What condition is C2002 over Roaring Brook in?

The National Bridge Inventory rates it in good condition. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted. The last reported inspection was in September 2024.

How much traffic does C2002 over Roaring Brook carry?

About 920 vehicles per day (2019 count), of which roughly 2% are trucks.

How long is C2002 over Roaring Brook?

The structure is 48 ft (14.6 m) long with a longest span of 45 ft (13.7 m) and a deck 29 ft wide.

Who owns C2002 over Roaring Brook?

It is owned by the Town or Township Highway Agency.