US Bridges

Sbl I-95 over Wilkinson Road

Fair

Henrico County, Virginia · 0.45 73 EB&0.84 (301)SB · Structure no. 000000000009832

Built
1962
63 years old
Condition
Fair
inspected November 2024
Type
Tee Beam
Concrete
Length
133 ft
3 main spans
Daily traffic
49,529
2022 count
Owner
State
State Highway Agency

About this bridge

Sbl I-95 over Wilkinson Road is a concrete tee beam carrying Sbl I-95 over Wilkinson Road in Henrico County, Virginia. It was built in 1962, so it is 63 years old, older than the Virginia average of 50.7 years.

The most recent inspection reported to the Federal Highway Administration rates it in fair condition with a lowest component rating of 5 out of 9. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

It carries about 49,529 vehicles a day, projected to reach 58,281 by 2042. The structure is 133 ft (40.5 m) long and 56 ft wide. If it were closed, the detour would be 1.2 mi (2 km).

CarriesSbl I-95
CrossesWilkinson Road
Location0.45 73 EB&0.84 (301)SB
RouteInterstate 95
Coordinates37.62951, -77.44912
Functional classUrban Principal Arterial - Interstate

Condition and inspection

Fair

The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

ComponentRatingMeaning
Deck6 SatisfactoryStructural elements show some minor deterioration.
Superstructure5 FairAll primary structural elements are sound but may have minor section loss, cracking, spalling or scour.
Substructure5 FairAll primary structural elements are sound but may have minor section loss, cracking, spalling or scour.
Last inspectionNovember 2024
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourBridge not over waterway
Structural evaluation5: Somewhat better than minimum adequacy to tolerate being left in place as is
Deck geometry6: Equal to present minimum criteria
Approach roadway alignment8: Equal to present desirable criteria
Operating rating48 US tons
Inventory rating35.1 US tons

Structure

Structure typeTee Beam
MaterialConcrete
DeckConcrete, cast-in-place
Main spans3
Design loadHS 20 + Mod
Structure length133 ft (40.5 m)
Longest span44 ft (13.4 m)
Deck width56 ft (17.1 m)
Roadway width54 ft (16.5 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic49,529 (2022)
Projected traffic58,281 by 2042
Trucks0%
Lanes on structure3
Traffic directionOne-way traffic
CarriesHighway
CrossesHighway
Detour if closed1.2 mi (2 km)
TollOn a free road
National Highway SystemYes
Strategic Highway NetworkInterstate STRAHNET route

Ownership and planned work

OwnerState Highway Agency
Maintained byState Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedNone recorded
Estimated improvement cost—
NavigationNot applicable (no waterway)

Frequently asked questions

When was Sbl I-95 over Wilkinson Road built?

It was built in 1962, making it 63 years old in 2025.

What condition is Sbl I-95 over Wilkinson Road in?

The National Bridge Inventory rates it in fair condition. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. The last reported inspection was in November 2024.

How much traffic does Sbl I-95 over Wilkinson Road carry?

About 49,529 vehicles per day (2022 count).

How long is Sbl I-95 over Wilkinson Road?

The structure is 133 ft (40.5 m) long with a longest span of 44 ft (13.4 m) and a deck 56 ft wide.

Who owns Sbl I-95 over Wilkinson Road?

It is owned by the State Highway Agency.