IH 35E SB FR over Drainage Ditch
GoodDallas County, Texas · 0.4 MI SE of W Belt Line · Structure no. 180570019603538
- Built
- 2019
- 6 years old
- Condition
- Good
- inspected April 2023
- Type
- Stringer/Multi-beam or Girder
- Prestressed Concrete
- Length
- 70 ft
- 1 main span
- Daily traffic
- 33,000
- 2019 count
- Owner
- State
- State Highway Agency
About this bridge
IH 35E SB FR over Drainage Ditch is a prestressed concrete stringer/multi-beam or girder carrying IH 35E SB FR over Drainage Ditch in Dallas County, Texas. It was built in 2019, so it is 6 years old, younger than the Texas average of 44.4 years.
The most recent inspection reported to the Federal Highway Administration rates it in good condition with a lowest component rating of 7 out of 9. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.
It carries about 33,000 vehicles a day, roughly 7% of them trucks, projected to reach 35,000 by 2040. The structure is 70 ft (21.3 m) long and 30 ft wide.
Location
Open in Google MapsCondition and inspection
All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.
| Component | Rating | Meaning |
|---|---|---|
| Deck | 7 Good | Some minor problems. |
| Superstructure | 8 Very Good | No problems noted. |
| Substructure | 7 Good | Some minor problems. |
| Channel and channel protection | 7 Good | Some minor problems. |
Structure
Traffic and service
Ownership and planned work
Frequently asked questions
When was IH 35E SB FR over Drainage Ditch built?
It was built in 2019, making it 6 years old in 2025.
What condition is IH 35E SB FR over Drainage Ditch in?
The National Bridge Inventory rates it in good condition. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted. The last reported inspection was in April 2023.
How much traffic does IH 35E SB FR over Drainage Ditch carry?
About 33,000 vehicles per day (2019 count), of which roughly 7% are trucks.
How long is IH 35E SB FR over Drainage Ditch?
The structure is 70 ft (21.3 m) long with a longest span of 70 ft (21.3 m) and a deck 30 ft wide.
Who owns IH 35E SB FR over Drainage Ditch?
It is owned by the State Highway Agency.