US Bridges

Cincinnati Ave over IH 10 Lower Level

Good

Bexar County, Texas · 0.30 MI N of SP 421 · Structure no. 150150007212037

Built
1949
76 years old
Condition
Good
inspected July 2024
Type
Tee Beam
Concrete Continuous
Length
99 ft
2 main spans
Daily traffic
6,371
2020 count
Owner
State
State Highway Agency

About this bridge

Cincinnati Ave over IH 10 Lower Level is a concrete continuous tee beam carrying Cincinnati Ave over IH 10 Lower Level in Bexar County, Texas. It was built in 1949, so it is 76 years old, older than the Texas average of 44.4 years.

The most recent inspection reported to the Federal Highway Administration rates it in good condition with a lowest component rating of 7 out of 9. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

It carries about 6,371 vehicles a day, roughly 3% of them trucks, projected to reach 8,919 by 2042. The structure is 99 ft (30.2 m) long and 64 ft wide.

CarriesCincinnati Ave
CrossesIH 10 Lower Level
Location0.30 MI N of SP 421
RouteCity Street 6795
StateTexas
Coordinates29.44859, -98.51515
Functional classUrban Minor Arterial

Condition and inspection

Good

All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

ComponentRatingMeaning
Deck7 GoodSome minor problems.
Superstructure7 GoodSome minor problems.
Substructure7 GoodSome minor problems.
Last inspectionJuly 2024
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourBridge not over waterway
Structural evaluation6: Equal to present minimum criteria
Deck geometry6: Equal to present minimum criteria
Approach roadway alignment8: Equal to present desirable criteria
Operating rating51 US tons
Inventory rating30 US tons

Structure

Structure typeTee Beam
MaterialConcrete Continuous
DeckConcrete, cast-in-place
Main spans2
Design loadOther
Structure length99 ft (30.2 m)
Longest span49 ft (14.9 m)
Deck width64 ft (19.6 m)
Roadway width50 ft (15.2 m)
Vertical clearance over deck20 ft (6 m)

Traffic and service

Average daily traffic6,371 (2020)
Projected traffic8,919 by 2042
Trucks3%
Lanes on structure3
Traffic directionTwo-way traffic
CarriesOverpass structure at an interchange
CrossesHighway
Detour if closed—
TollOn a free road
National Highway SystemNo

Ownership and planned work

OwnerState Highway Agency
Maintained byState Highway Agency
Historic statusPossibly eligible for the National Register; requires further investigation
Work proposedOther structural work, including hydraulic replacements
Estimated improvement cost$13,000
NavigationNot applicable (no waterway)

Frequently asked questions

When was Cincinnati Ave over IH 10 Lower Level built?

It was built in 1949, making it 76 years old in 2025.

What condition is Cincinnati Ave over IH 10 Lower Level in?

The National Bridge Inventory rates it in good condition. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted. The last reported inspection was in July 2024.

How much traffic does Cincinnati Ave over IH 10 Lower Level carry?

About 6,371 vehicles per day (2020 count), of which roughly 3% are trucks.

How long is Cincinnati Ave over IH 10 Lower Level?

The structure is 99 ft (30.2 m) long with a longest span of 49 ft (14.9 m) and a deck 64 ft wide.

Who owns Cincinnati Ave over IH 10 Lower Level?

It is owned by the State Highway Agency.