US Bridges

FAP 385 over SR-385 SB / SR-86

Fair

Shelby County, Tennessee · SR385/SR86 Intersection · Structure no. 79SR0860006

Built
2005
20 years old
Condition
Fair
inspected February 2025
Type
Stringer/Multi-beam or Girder
Steel Continuous
Length
391 ft
3 main spans
Daily traffic
26,993
2021 count
Owner
State
State Highway Agency

About this bridge

FAP 385 over SR-385 SB / SR-86 is a steel continuous stringer/multi-beam or girder carrying FAP 385 over SR-385 SB / SR-86 in Shelby County, Tennessee. It was built in 2005, so it is 20 years old, younger than the Tennessee average of 47.4 years.

The most recent inspection reported to the Federal Highway Administration rates it in fair condition with a lowest component rating of 6 out of 9. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

It carries about 26,993 vehicles a day, roughly 8% of them trucks, projected to reach 41,530 by 2041. The structure is 391 ft (119.2 m) long and 44 ft wide. If it were closed, the detour would be 0.6 mi (1 km).

CarriesFAP 385
CrossesSR-385 SB / SR-86
LocationSR385/SR86 Intersection
RouteState Highway 385
Coordinates35.02252, -89.65958
Functional classUrban Principal Arterial - Other Freeway or Expressway

Condition and inspection

Fair

The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

ComponentRatingMeaning
Deck6 SatisfactoryStructural elements show some minor deterioration.
Superstructure8 Very GoodNo problems noted.
Substructure6 SatisfactoryStructural elements show some minor deterioration.
Last inspectionFebruary 2025
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourBridge not over waterway
Structural evaluation6: Equal to present minimum criteria
Deck geometry8: Equal to present desirable criteria
Approach roadway alignment8: Equal to present desirable criteria
Operating rating59.5 US tons
Inventory rating35.7 US tons

Structure

MaterialSteel Continuous
DeckConcrete, precast panels
Main spans3
Design loadHS 20
Structure length391 ft (119.2 m)
Longest span185 ft (56.4 m)
Deck width44 ft (13.4 m)
Roadway width42 ft (12.8 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic26,993 (2021)
Projected traffic41,530 by 2041
Trucks8%
Lanes on structure2
Traffic directionOne-way traffic
CarriesHighway
CrossesHighway
Detour if closed0.6 mi (1 km)
TollOn a free road
National Highway SystemYes

Ownership and planned work

OwnerState Highway Agency
Maintained byState Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedNone recorded
Estimated improvement cost—
NavigationNot applicable (no waterway)

Frequently asked questions

When was FAP 385 over SR-385 SB / SR-86 built?

It was built in 2005, making it 20 years old in 2025.

What condition is FAP 385 over SR-385 SB / SR-86 in?

The National Bridge Inventory rates it in fair condition. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. The last reported inspection was in February 2025.

How much traffic does FAP 385 over SR-385 SB / SR-86 carry?

About 26,993 vehicles per day (2021 count), of which roughly 8% are trucks.

How long is FAP 385 over SR-385 SB / SR-86?

The structure is 391 ft (119.2 m) long with a longest span of 185 ft (56.4 m) and a deck 44 ft wide.

Who owns FAP 385 over SR-385 SB / SR-86?

It is owned by the State Highway Agency.