US Bridges

SR 2004 Horton Ave over Over Two Mile Run

Fair

Warren County, Pennsylvania · Sheffield T0WNSHIP · Structure no. 000000000034136

Built
1930
95 years old
Condition
Fair
inspected May 2023
Type
Stringer/Multi-beam or Girder
Steel
Length
38 ft
1 main span
Daily traffic
781
2024 count
Owner
State
State Highway Agency

About this bridge

SR 2004 Horton Ave over Over Two Mile Run is a steel stringer/multi-beam or girder carrying SR 2004 Horton Ave over Over Two Mile Run in Warren County, Pennsylvania. It was built in 1930, so it is 95 years old, older than the Pennsylvania average of 54.8 years.

The most recent inspection reported to the Federal Highway Administration rates it in fair condition with a lowest component rating of 5 out of 9. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

It carries about 781 vehicles a day, roughly 7% of them trucks, projected to reach 1,145 by 2032. The structure is 38 ft (11.6 m) long and 25 ft wide. If it were closed, the detour would be 5 mi (8 km).

CarriesSR 2004 Horton Ave
CrossesOver Two Mile Run
LocationSheffield T0WNSHIP
RouteState Highway 0
Coordinates41.70435, -79.02221
Functional classRural Local

Condition and inspection

Fair

The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

ComponentRatingMeaning
Deck5 FairAll primary structural elements are sound but may have minor section loss, cracking, spalling or scour.
Superstructure5 FairAll primary structural elements are sound but may have minor section loss, cracking, spalling or scour.
Substructure5 FairAll primary structural elements are sound but may have minor section loss, cracking, spalling or scour.
Channel and channel protection5 FairAll primary structural elements are sound but may have minor section loss, cracking, spalling or scour.
Last inspectionMay 2023
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourFoundations stable; action required to protect exposed foundations
Structural evaluation5: Somewhat better than minimum adequacy to tolerate being left in place as is
Deck geometry3: Basically intolerable, requiring high priority of corrective action
Waterway adequacy7: Better than present minimum criteria
Approach roadway alignment8: Equal to present desirable criteria
Operating rating54 US tons
Inventory rating31 US tons

Structure

MaterialSteel
DeckConcrete, cast-in-place
Main spans1
Design loadH 20
Structure length38 ft (11.6 m)
Longest span35 ft (10.7 m)
Deck width25 ft (7.5 m)
Roadway width22 ft (6.6 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic781 (2024)
Projected traffic1,145 by 2032
Trucks7%
Lanes on structure2
Traffic directionTwo-way traffic
CarriesHighway
CrossesWaterway
Detour if closed5 mi (8 km)
TollOn a free road
National Highway SystemNo

Ownership and planned work

OwnerState Highway Agency
Maintained byState Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedRehabilitation because of general structure deterioration or inadequate strength
Estimated improvement cost$37,000
NavigationNo navigation control on waterway

Frequently asked questions

When was SR 2004 Horton Ave over Over Two Mile Run built?

It was built in 1930, making it 95 years old in 2025.

What condition is SR 2004 Horton Ave over Over Two Mile Run in?

The National Bridge Inventory rates it in fair condition. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. The last reported inspection was in May 2023.

How much traffic does SR 2004 Horton Ave over Over Two Mile Run carry?

About 781 vehicles per day (2024 count), of which roughly 7% are trucks.

How long is SR 2004 Horton Ave over Over Two Mile Run?

The structure is 38 ft (11.6 m) long with a longest span of 35 ft (10.7 m) and a deck 25 ft wide.

Who owns SR 2004 Horton Ave over Over Two Mile Run?

It is owned by the State Highway Agency.