US Bridges

SR 2002 High St. over Over Tionesta Creek

Fair

Warren County, Pennsylvania · Sheffield Township · Structure no. 000000000034135

Built
1937
88 years old, rebuilt 1982
Condition
Fair
inspected July 2024
Type
Truss - Thru
Steel
Length
108 ft
1 main span
Daily traffic
216
2024 count
Owner
State
State Highway Agency

About this bridge

SR 2002 High St. over Over Tionesta Creek is a steel truss - thru carrying SR 2002 High St. over Over Tionesta Creek in Warren County, Pennsylvania. It was built in 1937 and reconstructed in 1982, so it is 88 years old, older than the Pennsylvania average of 54.8 years.

The most recent inspection reported to the Federal Highway Administration rates it in fair condition with a lowest component rating of 5 out of 9. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

It carries about 216 vehicles a day, roughly 5% of them trucks, projected to reach 381 by 2032. The structure is 108 ft (32.9 m) long and 30 ft wide. If it were closed, the detour would be 8.1 mi (13 km).

CarriesSR 2002 High St.
CrossesOver Tionesta Creek
LocationSheffield Township
RouteState Highway 0
Coordinates41.70204, -79.03545
Functional classRural Minor Collector

Condition and inspection

Fair

The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

ComponentRatingMeaning
Deck7 GoodSome minor problems.
Superstructure5 FairAll primary structural elements are sound but may have minor section loss, cracking, spalling or scour.
Substructure5 FairAll primary structural elements are sound but may have minor section loss, cracking, spalling or scour.
Channel and channel protection5 FairAll primary structural elements are sound but may have minor section loss, cracking, spalling or scour.
Last inspectionJuly 2024
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourCountermeasures installed to correct a previously existing problem
Structural evaluation5: Somewhat better than minimum adequacy to tolerate being left in place as is
Deck geometry4: Meets minimum tolerable limits to be left in place as is
Waterway adequacy7: Better than present minimum criteria
Approach roadway alignment4: Meets minimum tolerable limits to be left in place as is
Operating rating60 US tons
Inventory rating36 US tons

Structure

Structure typeTruss - Thru
MaterialSteel
DeckConcrete, cast-in-place
Main spans1
Design loadHS 20
Structure length108 ft (32.9 m)
Longest span104 ft (31.7 m)
Deck width30 ft (9.1 m)
Roadway width23 ft (7 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic216 (2024)
Projected traffic381 by 2032
Trucks5%
Lanes on structure2
Traffic directionTwo-way traffic
CarriesHighway and pedestrian
CrossesWaterway
Detour if closed8.1 mi (13 km)
TollOn a free road
National Highway SystemNo

Ownership and planned work

OwnerState Highway Agency
Maintained byState Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedNone recorded
Estimated improvement cost—
NavigationNo navigation control on waterway

Frequently asked questions

When was SR 2002 High St. over Over Tionesta Creek built?

It was built in 1937, making it 88 years old in 2025. It was reconstructed in 1982.

What condition is SR 2002 High St. over Over Tionesta Creek in?

The National Bridge Inventory rates it in fair condition. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. The last reported inspection was in July 2024.

How much traffic does SR 2002 High St. over Over Tionesta Creek carry?

About 216 vehicles per day (2024 count), of which roughly 5% are trucks.

How long is SR 2002 High St. over Over Tionesta Creek?

The structure is 108 ft (32.9 m) long with a longest span of 104 ft (31.7 m) and a deck 30 ft wide.

Who owns SR 2002 High St. over Over Tionesta Creek?

It is owned by the State Highway Agency.