US Bridges

Rampkk(sb - Off) over I-95;INDUSTRIAL Hwy;ramp

Fair

Philadelphia County, Pennsylvania · N.High Speed Line 3698K10 · Structure no. 000000000039439

Built
1983
42 years old
Condition
Fair
inspected June 2024
Type
Stringer/Multi-beam or Girder
Prestressed Concrete Continuous
Length
1,060 ft
4 main spans
Daily traffic
4,011
2024 count
Owner
State
State Highway Agency

About this bridge

Rampkk(sb - Off) over I-95;INDUSTRIAL Hwy;ramp is a prestressed concrete continuous stringer/multi-beam or girder carrying Rampkk(sb - Off) over I-95;INDUSTRIAL Hwy;ramp in Philadelphia County, Pennsylvania. It was built in 1983, so it is 42 years old, younger than the Pennsylvania average of 54.8 years.

The most recent inspection reported to the Federal Highway Administration rates it in fair condition with a lowest component rating of 5 out of 9. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

It carries about 4,011 vehicles a day, roughly 1% of them trucks, projected to reach 5,010 by 2032. The structure is 1,060 ft (323.1 m) long and 44 ft wide. If it were closed, the detour would be 1.9 mi (3 km).

CarriesRampkk(sb - Off)
CrossesI-95;INDUSTRIAL Hwy;ramp
LocationN.High Speed Line 3698K10
RouteState Highway 0
Coordinates39.87745, -75.25291
Functional classUrban Principal Arterial - Interstate

Condition and inspection

Fair

The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

ComponentRatingMeaning
Deck5 FairAll primary structural elements are sound but may have minor section loss, cracking, spalling or scour.
Superstructure5 FairAll primary structural elements are sound but may have minor section loss, cracking, spalling or scour.
Substructure6 SatisfactoryStructural elements show some minor deterioration.
Last inspectionJune 2024
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourBridge not over waterway
Structural evaluation4: Meets minimum tolerable limits to be left in place as is
Deck geometry9: Superior to present desirable criteria
Approach roadway alignment7: Better than present minimum criteria
Operating rating78 US tons
Inventory rating21.1 US tons

Structure

MaterialPrestressed Concrete Continuous
DeckConcrete, cast-in-place
Main spans4 (+5 approach)
Design loadHS 20
Structure length1,060 ft (323.1 m)
Longest span135 ft (41.1 m)
Deck width44 ft (13.3 m)
Roadway width41 ft (12.6 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic4,011 (2024)
Projected traffic5,010 by 2032
Trucks1%
Lanes on structure1
Traffic directionOne-way traffic
CarriesHighway
CrossesHighway
Detour if closed1.9 mi (3 km)
TollOn a free road
National Highway SystemYes

Ownership and planned work

OwnerState Highway Agency
Maintained byState Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedRehabilitation because of general structure deterioration or inadequate strength
Estimated improvement cost$642,000
NavigationNot applicable (no waterway)

Frequently asked questions

When was Rampkk(sb - Off) over I-95;INDUSTRIAL Hwy;ramp built?

It was built in 1983, making it 42 years old in 2025.

What condition is Rampkk(sb - Off) over I-95;INDUSTRIAL Hwy;ramp in?

The National Bridge Inventory rates it in fair condition. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. The last reported inspection was in June 2024.

How much traffic does Rampkk(sb - Off) over I-95;INDUSTRIAL Hwy;ramp carry?

About 4,011 vehicles per day (2024 count), of which roughly 1% are trucks.

How long is Rampkk(sb - Off) over I-95;INDUSTRIAL Hwy;ramp?

The structure is 1,060 ft (323.1 m) long with a longest span of 135 ft (41.1 m) and a deck 44 ft wide.

Who owns Rampkk(sb - Off) over I-95;INDUSTRIAL Hwy;ramp?

It is owned by the State Highway Agency.