US Bridges

Henry Avenue over Septa;csx and Creek

Fair

Philadelphia County, Pennsylvania · N.Hunting Park AVE3480B09 · Structure no. 000000000039030

Built
1930
95 years old, rebuilt 2011
Condition
Fair
inspected August 2022
Type
Girder and Floorbeam System
Steel
Length
569 ft
5 main spans
Daily traffic
17,474
2024 count
Owner
State
State Highway Agency

About this bridge

Henry Avenue over Septa;csx and Creek is a steel girder and floorbeam system carrying Henry Avenue over Septa;csx and Creek in Philadelphia County, Pennsylvania. It was built in 1930 and reconstructed in 2011, so it is 95 years old, older than the Pennsylvania average of 54.8 years.

The most recent inspection reported to the Federal Highway Administration rates it in fair condition with a lowest component rating of 5 out of 9. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

It carries about 17,474 vehicles a day, roughly 5% of them trucks, projected to reach 18,413 by 2032. The structure is 569 ft (173.4 m) long and 100 ft wide. If it were closed, the detour would be 1.9 mi (3 km).

CarriesHenry Avenue
CrossesSepta;csx and Creek
LocationN.Hunting Park AVE3480B09
RouteState Highway 0
Coordinates40.00733, -75.17939
Functional classUrban Other Principal Arterial

Condition and inspection

Fair

The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

ComponentRatingMeaning
Deck5 FairAll primary structural elements are sound but may have minor section loss, cracking, spalling or scour.
Superstructure5 FairAll primary structural elements are sound but may have minor section loss, cracking, spalling or scour.
Substructure6 SatisfactoryStructural elements show some minor deterioration.
Channel and channel protection6 SatisfactoryStructural elements show some minor deterioration.
Last inspectionAugust 2022
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourFoundations stable; scour above top of footing
Structural evaluation5: Somewhat better than minimum adequacy to tolerate being left in place as is
Deck geometry9: Superior to present desirable criteria
Waterway adequacy9: Superior to present desirable criteria
Approach roadway alignment8: Equal to present desirable criteria
Operating rating49.1 US tons
Inventory rating29 US tons

Structure

MaterialSteel
DeckConcrete, cast-in-place
Main spans5 (+4 approach)
Design loadH 20
Structure length569 ft (173.4 m)
Longest span93 ft (28.3 m)
Deck width100 ft (30.6 m)
Roadway width76 ft (23.2 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic17,474 (2024)
Projected traffic18,413 by 2032
Trucks5%
Lanes on structure4
Traffic directionTwo-way traffic
CarriesHighway and pedestrian
CrossesRailroad and waterway
Detour if closed1.9 mi (3 km)
TollOn a free road
National Highway SystemYes

Ownership and planned work

OwnerState Highway Agency
Maintained byState Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedRehabilitation because of general structure deterioration or inadequate strength
Estimated improvement cost$4.2 million
NavigationNo navigation control on waterway

Frequently asked questions

When was Henry Avenue over Septa;csx and Creek built?

It was built in 1930, making it 95 years old in 2025. It was reconstructed in 2011.

What condition is Henry Avenue over Septa;csx and Creek in?

The National Bridge Inventory rates it in fair condition. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. The last reported inspection was in August 2022.

How much traffic does Henry Avenue over Septa;csx and Creek carry?

About 17,474 vehicles per day (2024 count), of which roughly 5% are trucks.

How long is Henry Avenue over Septa;csx and Creek?

The structure is 569 ft (173.4 m) long with a longest span of 93 ft (28.3 m) and a deck 100 ft wide.

Who owns Henry Avenue over Septa;csx and Creek?

It is owned by the State Highway Agency.