US Bridges

SR 2001 over Sideling Hill Creek

Good

Huntingdon County, Pennsylvania · 3 MI S of Selea · Structure no. 000000000057239

Built
2019
6 years old
Condition
Good
inspected May 2023
Type
Box Beam or Girders - Multiple
Prestressed Concrete
Length
86 ft
1 main span
Daily traffic
245
2024 count
Owner
State
State Highway Agency

About this bridge

SR 2001 over Sideling Hill Creek is a prestressed concrete box beam or girders - multiple carrying SR 2001 over Sideling Hill Creek in Huntingdon County, Pennsylvania. It was built in 2019, so it is 6 years old, younger than the Pennsylvania average of 54.8 years.

The most recent inspection reported to the Federal Highway Administration rates it in good condition with a lowest component rating of 8 out of 9. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

It carries about 245 vehicles a day, roughly 7% of them trucks, projected to reach 200 by 2030. The structure is 86 ft (26.2 m) long and 31 ft wide. If it were closed, the detour would be 3.1 mi (5 km).

CarriesSR 2001
CrossesSideling Hill Creek
Location3 MI S of Selea
RouteState Highway 0
Coordinates40.12194, -78.02443
Functional classRural Local

Condition and inspection

Good

All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

ComponentRatingMeaning
Deck8 Very GoodNo problems noted.
Superstructure8 Very GoodNo problems noted.
Substructure8 Very GoodNo problems noted.
Channel and channel protection7 GoodSome minor problems.
Last inspectionMay 2023
Inspection intervalevery 48 months
Operating statusOpen, no restriction
ScourFoundations stable; scour above top of footing
Structural evaluation8: Equal to present desirable criteria
Deck geometry6: Equal to present minimum criteria
Waterway adequacy8: Equal to present desirable criteria
Approach roadway alignment5: Somewhat better than minimum adequacy to tolerate being left in place as is
Operating rating61.8 US tons
Inventory rating44.3 US tons

Structure

MaterialPrestressed Concrete
DeckConcrete, cast-in-place
Main spans1
Design loadHL 93
Structure length86 ft (26.2 m)
Longest span84 ft (25.6 m)
Deck width31 ft (9.6 m)
Roadway width28 ft (8.5 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic245 (2024)
Projected traffic200 by 2030
Trucks7%
Lanes on structure2
Traffic directionTwo-way traffic
CarriesHighway
CrossesWaterway
Detour if closed3.1 mi (5 km)
TollOn a free road
National Highway SystemNo

Ownership and planned work

OwnerState Highway Agency
Maintained byState Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedNone recorded
Estimated improvement cost—
NavigationNo navigation control on waterway

Frequently asked questions

When was SR 2001 over Sideling Hill Creek built?

It was built in 2019, making it 6 years old in 2025.

What condition is SR 2001 over Sideling Hill Creek in?

The National Bridge Inventory rates it in good condition. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted. The last reported inspection was in May 2023.

How much traffic does SR 2001 over Sideling Hill Creek carry?

About 245 vehicles per day (2024 count), of which roughly 7% are trucks.

How long is SR 2001 over Sideling Hill Creek?

The structure is 86 ft (26.2 m) long with a longest span of 84 ft (25.6 m) and a deck 31 ft wide.

Who owns SR 2001 over Sideling Hill Creek?

It is owned by the State Highway Agency.