US Bridges

SR 4011 over Sideling Hill Creek

Good

Fulton County, Pennsylvania · .8 Mi.E.Of Waterfall · Structure no. 000000000039659

Built
1997
28 years old
Condition
Good
inspected December 2023
Type
Box Beam or Girders - Multiple
Prestressed Concrete
Length
78 ft
1 main span
Daily traffic
116
2024 count
Owner
State
State Highway Agency

About this bridge

SR 4011 over Sideling Hill Creek is a prestressed concrete box beam or girders - multiple carrying SR 4011 over Sideling Hill Creek in Fulton County, Pennsylvania. It was built in 1997, so it is 28 years old, younger than the Pennsylvania average of 54.8 years.

The most recent inspection reported to the Federal Highway Administration rates it in good condition with a lowest component rating of 7 out of 9. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

It carries about 116 vehicles a day, roughly 12% of them trucks, projected to reach 132 by 2032. The structure is 78 ft (23.8 m) long and 33 ft wide. If it were closed, the detour would be 6.2 mi (10 km).

CarriesSR 4011
CrossesSideling Hill Creek
Location.8 Mi.E.Of Waterfall
RouteState Highway 0
Coordinates40.12527, -78.04687
Functional classRural Local

Condition and inspection

Good

All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

ComponentRatingMeaning
Deck7 GoodSome minor problems.
Superstructure8 Very GoodNo problems noted.
Substructure8 Very GoodNo problems noted.
Channel and channel protection6 SatisfactoryStructural elements show some minor deterioration.
Last inspectionDecember 2023
Inspection intervalevery 48 months
Operating statusOpen, no restriction
ScourFoundations stable; scour above top of footing
Structural evaluation8: Equal to present desirable criteria
Deck geometry6: Equal to present minimum criteria
Waterway adequacy9: Superior to present desirable criteria
Approach roadway alignment8: Equal to present desirable criteria
Operating rating96 US tons
Inventory rating50 US tons

Structure

MaterialPrestressed Concrete
DeckConcrete, cast-in-place
Main spans1
Design loadHS 25 or greater
Structure length78 ft (23.8 m)
Longest span75 ft (22.9 m)
Deck width33 ft (10.2 m)
Roadway width30 ft (9.1 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic116 (2024)
Projected traffic132 by 2032
Trucks12%
Lanes on structure2
Traffic directionTwo-way traffic
CarriesHighway
CrossesWaterway
Detour if closed6.2 mi (10 km)
TollOn a free road
National Highway SystemNo

Ownership and planned work

OwnerState Highway Agency
Maintained byState Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedNone recorded
Estimated improvement cost—
NavigationNo navigation control on waterway

Frequently asked questions

When was SR 4011 over Sideling Hill Creek built?

It was built in 1997, making it 28 years old in 2025.

What condition is SR 4011 over Sideling Hill Creek in?

The National Bridge Inventory rates it in good condition. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted. The last reported inspection was in December 2023.

How much traffic does SR 4011 over Sideling Hill Creek carry?

About 116 vehicles per day (2024 count), of which roughly 12% are trucks.

How long is SR 4011 over Sideling Hill Creek?

The structure is 78 ft (23.8 m) long with a longest span of 75 ft (22.9 m) and a deck 33 ft wide.

Who owns SR 4011 over Sideling Hill Creek?

It is owned by the State Highway Agency.