RTE I495 over RTE I295 RTE I295
FairQueens County, New York · JCT I495+I78 · Structure no. 000000001055230
- Built
- 1960
- 65 years old, rebuilt 1990
- Condition
- Fair
- inspected February 2024
- Type
- Stringer/Multi-beam or Girder
- Steel
- Length
- 128 ft
- 2 main spans
- Daily traffic
- 2,782
- 2020 count
- Owner
- State
- State Highway Agency
About this bridge
RTE I495 over RTE I295 RTE I295 is a steel stringer/multi-beam or girder carrying RTE I495 over RTE I295 RTE I295 in Queens County, New York. It was built in 1960 and reconstructed in 1990, so it is 65 years old, older than the New York average of 53 years.
The most recent inspection reported to the Federal Highway Administration rates it in fair condition with a lowest component rating of 6 out of 9. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.
It carries about 2,782 vehicles a day, roughly 10% of them trucks, projected to reach 3,554 by 2041. The structure is 128 ft (39 m) long and 27 ft wide. If it were closed, the detour would be 1.9 mi (3 km).
Location
Open in Google MapsCondition and inspection
The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.
| Component | Rating | Meaning |
|---|---|---|
| Deck | 6 Satisfactory | Structural elements show some minor deterioration. |
| Superstructure | 6 Satisfactory | Structural elements show some minor deterioration. |
| Substructure | 6 Satisfactory | Structural elements show some minor deterioration. |
Structure
Traffic and service
Ownership and planned work
Frequently asked questions
When was RTE I495 over RTE I295 RTE I295 built?
It was built in 1960, making it 65 years old in 2025. It was reconstructed in 1990.
What condition is RTE I495 over RTE I295 RTE I295 in?
The National Bridge Inventory rates it in fair condition. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. The last reported inspection was in February 2024.
How much traffic does RTE I495 over RTE I295 RTE I295 carry?
About 2,782 vehicles per day (2020 count), of which roughly 10% are trucks.
How long is RTE I495 over RTE I295 RTE I295?
The structure is 128 ft (39 m) long with a longest span of 69 ft (21 m) and a deck 27 ft wide.
Who owns RTE I495 over RTE I295 RTE I295?
It is owned by the State Highway Agency.