US Bridges

Sutton Road over 390I390142021320 RTE I3

Good

Livingston County, New York · 1.7 MI NE Jct.Rts 390I&15 · Structure no. 000000001071170

Built
1980
45 years old
Condition
Good
inspected June 2023
Type
Stringer/Multi-beam or Girder
Steel Continuous
Length
252 ft
2 main spans
Daily traffic
447
2021 count
Owner
State
State Highway Agency

About this bridge

Sutton Road over 390I390142021320 RTE I3 is a steel continuous stringer/multi-beam or girder carrying Sutton Road over 390I390142021320 RTE I3 in Livingston County, New York. It was built in 1980, so it is 45 years old, younger than the New York average of 53 years.

The most recent inspection reported to the Federal Highway Administration rates it in good condition with a lowest component rating of 7 out of 9. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

It carries about 447 vehicles a day, roughly 7% of them trucks, projected to reach 626 by 2041. The structure is 252 ft (76.8 m) long and 38 ft wide. If it were closed, the detour would be 1.9 mi (3 km).

CarriesSutton Road
Crosses390I390142021320 RTE I3
Location1.7 MI NE Jct.Rts 390I&15
RouteCounty Highway 0
Coordinates42.88605, -77.69576
Functional classRural Minor Collector

Condition and inspection

Good

All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

ComponentRatingMeaning
Deck7 GoodSome minor problems.
Superstructure7 GoodSome minor problems.
Substructure7 GoodSome minor problems.
Last inspectionJune 2023
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourBridge not over waterway
Structural evaluation7: Better than present minimum criteria
Deck geometry6: Equal to present minimum criteria
Approach roadway alignment8: Equal to present desirable criteria
Operating rating75.9 US tons
Inventory rating45 US tons

Structure

MaterialSteel Continuous
DeckConcrete, cast-in-place
Main spans2
Design loadHS 20
Structure length252 ft (76.8 m)
Longest span124 ft (37.7 m)
Deck width38 ft (11.6 m)
Roadway width35 ft (10.7 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic447 (2021)
Projected traffic626 by 2041
Trucks7%
Lanes on structure2
Traffic directionTwo-way traffic
CarriesHighway
CrossesHighway
Detour if closed1.9 mi (3 km)
TollOn a free road
National Highway SystemNo

Ownership and planned work

OwnerState Highway Agency
Maintained byState Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedWidening with deck rehabilitation or replacement
Estimated improvement cost$4.1 million (2024 estimate)
NavigationNot applicable (no waterway)

Frequently asked questions

When was Sutton Road over 390I390142021320 RTE I3 built?

It was built in 1980, making it 45 years old in 2025.

What condition is Sutton Road over 390I390142021320 RTE I3 in?

The National Bridge Inventory rates it in good condition. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted. The last reported inspection was in June 2023.

How much traffic does Sutton Road over 390I390142021320 RTE I3 carry?

About 447 vehicles per day (2021 count), of which roughly 7% are trucks.

How long is Sutton Road over 390I390142021320 RTE I3?

The structure is 252 ft (76.8 m) long with a longest span of 124 ft (37.7 m) and a deck 38 ft wide.

Who owns Sutton Road over 390I390142021320 RTE I3?

It is owned by the State Highway Agency.