US Bridges

Sno & Sni Rwys over Main ST Edison

Fair

Middlesex County, New Jersey · 0.8 MI S of Int. 10 · Structure no. M08727N

Built
1974
51 years old
Condition
Fair
inspected April 2023
Type
Stringer/Multi-beam or Girder
Steel
Length
131 ft
3 main spans
Daily traffic
101,869
2023 count
Owner
Toll Authority
State Toll Authority

About this bridge

Sno & Sni Rwys over Main ST Edison is a steel stringer/multi-beam or girder carrying Sno & Sni Rwys over Main ST Edison in Middlesex County, New Jersey. It was built in 1974, so it is 51 years old, younger than the New Jersey average of 58.5 years.

The most recent inspection reported to the Federal Highway Administration rates it in fair condition with a lowest component rating of 5 out of 9. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

It carries about 101,869 vehicles a day, roughly 10% of them trucks, projected to reach 143,913 by 2043. The structure is 131 ft (39.9 m) long and 126 ft wide. If it were closed, the detour would be 1.2 mi (2 km).

CarriesSno & Sni Rwys
CrossesMain ST Edison
Location0.8 MI S of Int. 10
RouteInterstate 95
Coordinates40.51988, -74.35661
Functional classUrban Principal Arterial - Interstate

Condition and inspection

Fair

The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

ComponentRatingMeaning
Deck7 GoodSome minor problems.
Superstructure5 FairAll primary structural elements are sound but may have minor section loss, cracking, spalling or scour.
Substructure5 FairAll primary structural elements are sound but may have minor section loss, cracking, spalling or scour.
Last inspectionApril 2023
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourBridge not over waterway
Structural evaluation5: Somewhat better than minimum adequacy to tolerate being left in place as is
Deck geometry9: Superior to present desirable criteria
Approach roadway alignment8: Equal to present desirable criteria
Operating rating50.7 US tons
Inventory rating38.9 US tons

Structure

MaterialSteel
DeckConcrete, cast-in-place
Main spans3
Design loadHS 20
Structure length131 ft (39.9 m)
Longest span46 ft (14 m)
Deck width126 ft (38.3 m)
Roadway width122 ft (37.1 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic101,869 (2023)
Projected traffic143,913 by 2043
Trucks10%
Lanes on structure6
Traffic directionOne-way traffic
CarriesHighway
CrossesHighway
Detour if closed1.2 mi (2 km)
TollOn a toll road
National Highway SystemYes
Strategic Highway NetworkInterstate STRAHNET route

Ownership and planned work

OwnerState Toll Authority
Maintained byState Toll Authority
Historic statusNot eligible for the National Register of Historic Places
Work proposedNone recorded
Estimated improvement cost—
NavigationNot applicable (no waterway)

Frequently asked questions

When was Sno & Sni Rwys over Main ST Edison built?

It was built in 1974, making it 51 years old in 2025.

What condition is Sno & Sni Rwys over Main ST Edison in?

The National Bridge Inventory rates it in fair condition. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. The last reported inspection was in April 2023.

How much traffic does Sno & Sni Rwys over Main ST Edison carry?

About 101,869 vehicles per day (2023 count), of which roughly 10% are trucks.

How long is Sno & Sni Rwys over Main ST Edison?

The structure is 131 ft (39.9 m) long with a longest span of 46 ft (14 m) and a deck 126 ft wide.

Who owns Sno & Sni Rwys over Main ST Edison?

It is owned by the State Toll Authority.