US Bridges

I-195 Ramp P over South Broad ST E.B.

Fair

Mercer County, New Jersey · 0.63 MI E of Rt 206 JCT · Structure no. 1134155

Built
1988
37 years old
Condition
Fair
inspected April 2023
Type
Stringer/Multi-beam or Girder
Steel
Length
122 ft
1 main span
Daily traffic
3,890
2023 count
Owner
State
State Highway Agency

About this bridge

I-195 Ramp P over South Broad ST E.B. is a steel stringer/multi-beam or girder carrying I-195 Ramp P over South Broad ST E.B. in Mercer County, New Jersey. It was built in 1988, so it is 37 years old, younger than the New Jersey average of 58.5 years.

The most recent inspection reported to the Federal Highway Administration rates it in fair condition with a lowest component rating of 6 out of 9. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

It carries about 3,890 vehicles a day, roughly 9% of them trucks, projected to reach 5,468 by 2043. The structure is 122 ft (37.2 m) long and 28 ft wide. If it were closed, the detour would be 3.1 mi (5 km).

CarriesI-195 Ramp P
CrossesSouth Broad ST E.B.
Location0.63 MI E of Rt 206 JCT
RouteInterstate 195
Coordinates40.18681, -74.69367
Functional classUrban Principal Arterial - Interstate

Condition and inspection

Fair

The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

ComponentRatingMeaning
Deck7 GoodSome minor problems.
Superstructure6 SatisfactoryStructural elements show some minor deterioration.
Substructure7 GoodSome minor problems.
Last inspectionApril 2023
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourBridge not over waterway
Structural evaluation6: Equal to present minimum criteria
Deck geometry7: Better than present minimum criteria
Approach roadway alignment6: Equal to present minimum criteria
Operating rating110.1 US tons
Inventory rating75.9 US tons

Structure

MaterialSteel
DeckConcrete, cast-in-place
Main spans1
Design loadHS 20 + Mod
Structure length122 ft (37.2 m)
Longest span119 ft (36.3 m)
Deck width28 ft (8.4 m)
Roadway width24 ft (7.3 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic3,890 (2023)
Projected traffic5,468 by 2043
Trucks9%
Lanes on structure1
Traffic directionOne-way traffic
CarriesHighway
CrossesHighway
Detour if closed3.1 mi (5 km)
TollOn a free road
National Highway SystemYes

Ownership and planned work

OwnerState Highway Agency
Maintained byState Highway Agency
Historic statusHistorical significance not determinable at this time
Work proposedNone recorded
Estimated improvement cost—
NavigationNot applicable (no waterway)

Frequently asked questions

When was I-195 Ramp P over South Broad ST E.B. built?

It was built in 1988, making it 37 years old in 2025.

What condition is I-195 Ramp P over South Broad ST E.B. in?

The National Bridge Inventory rates it in fair condition. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. The last reported inspection was in April 2023.

How much traffic does I-195 Ramp P over South Broad ST E.B. carry?

About 3,890 vehicles per day (2023 count), of which roughly 9% are trucks.

How long is I-195 Ramp P over South Broad ST E.B.?

The structure is 122 ft (37.2 m) long with a longest span of 119 ft (36.3 m) and a deck 28 ft wide.

Who owns I-195 Ramp P over South Broad ST E.B.?

It is owned by the State Highway Agency.