US Bridges

Third Level Entran over Hourly Parking Garage

Good

Anne Arundel County, Maryland · Bwi Hourly Park Garage · Structure no. 300000AAMA09010

Built
1995
30 years old
Condition
Good
inspected June 2024
Type
Tee Beam
Concrete Continuous
Length
26 ft
2 main spans
Daily traffic
1,300
2024 count
Owner
State
Other State Agency

About this bridge

Third Level Entran over Hourly Parking Garage is a concrete continuous tee beam carrying Third Level Entran over Hourly Parking Garage in Anne Arundel County, Maryland. It was built in 1995, so it is 30 years old, younger than the Maryland average of 52.6 years.

The most recent inspection reported to the Federal Highway Administration rates it in good condition with a lowest component rating of 7 out of 9. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

It carries about 1,300 vehicles a day, projected to reach 1,940 by 2044. The structure is 26 ft (7.9 m) long and 27 ft wide.

CarriesThird Level Entran
CrossesHourly Parking Garage
LocationBwi Hourly Park Garage
Coordinates39.18144, -76.67118
Functional classUrban Local

Condition and inspection

Good

All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

ComponentRatingMeaning
Deck7 GoodSome minor problems.
Superstructure7 GoodSome minor problems.
Substructure7 GoodSome minor problems.
Last inspectionJune 2024
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourBridge not over waterway
Structural evaluation7: Better than present minimum criteria
Deck geometry2: Basically intolerable, requiring high priority of replacement
Approach roadway alignment8: Equal to present desirable criteria
Operating rating110.1 US tons
Inventory rating72.5 US tons

Structure

Structure typeTee Beam
MaterialConcrete Continuous
DeckConcrete, cast-in-place
Main spans2 (+1 approach)
Design loadHS 20
Structure length26 ft (7.9 m)
Longest span20 ft (6.1 m)
Deck width27 ft (8.3 m)
Roadway width24 ft (7.3 m)
Vertical clearance over deck6 ft (1.8 m)

Traffic and service

Average daily traffic1,300 (2024)
Projected traffic1,940 by 2044
Trucks0%
Lanes on structure2
Traffic directionOne-way traffic
CarriesHighway
CrossesOther
Detour if closed—
TollOn a toll road
National Highway SystemNo

Ownership and planned work

OwnerOther State Agency
Maintained byOther State Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedNone recorded
Estimated improvement cost—
NavigationNot applicable (no waterway)

Frequently asked questions

When was Third Level Entran over Hourly Parking Garage built?

It was built in 1995, making it 30 years old in 2025.

What condition is Third Level Entran over Hourly Parking Garage in?

The National Bridge Inventory rates it in good condition. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted. The last reported inspection was in June 2024.

How much traffic does Third Level Entran over Hourly Parking Garage carry?

About 1,300 vehicles per day (2024 count).

How long is Third Level Entran over Hourly Parking Garage?

The structure is 26 ft (7.9 m) long with a longest span of 20 ft (6.1 m) and a deck 27 ft wide.

Who owns Third Level Entran over Hourly Parking Garage?

It is owned by the Other State Agency.