US Bridges

Industrial Drive over Cooley Creek

Fair

Webster Parish, Louisiana · 0.7 MI SE of LA 7 · Structure no. 046032353931691

Built
1995
30 years old
Condition
Fair
inspected July 2023
Type
Slab
Concrete
Length
220 ft
11 main spans
Daily traffic
68
2020 count
Owner
City
City or Municipal Highway Agency

About this bridge

Industrial Drive over Cooley Creek is a concrete slab carrying Industrial Drive over Cooley Creek in Webster Parish, Louisiana. It was built in 1995, so it is 30 years old, younger than the Louisiana average of 43 years.

The most recent inspection reported to the Federal Highway Administration rates it in fair condition with a lowest component rating of 6 out of 9. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

It carries about 68 vehicles a day, projected to reach 74 by 2040. The structure is 220 ft (67.1 m) long and 31 ft wide. If it were closed, the detour would be 1.2 mi (2 km).

CarriesIndustrial Drive
CrossesCooley Creek
Location0.7 MI SE of LA 7
RouteCounty Highway 0
Coordinates32.58934, -93.28141
Functional classUrban Other Principal Arterial

Condition and inspection

Fair

The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

ComponentRatingMeaning
Deck6 SatisfactoryStructural elements show some minor deterioration.
Superstructure6 SatisfactoryStructural elements show some minor deterioration.
Substructure6 SatisfactoryStructural elements show some minor deterioration.
Channel and channel protection6 SatisfactoryStructural elements show some minor deterioration.
Last inspectionJuly 2023
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourScour critical; foundations unstable for calculated scour conditions
Structural evaluation6: Equal to present minimum criteria
Deck geometry7: Better than present minimum criteria
Waterway adequacy8: Equal to present desirable criteria
Approach roadway alignment8: Equal to present desirable criteria
Operating rating44.3 US tons
Inventory rating34.3 US tons

Structure

Structure typeSlab
MaterialConcrete
DeckConcrete, cast-in-place
Main spans11
Design loadHS 20
Structure length220 ft (67.1 m)
Longest span20 ft (6.1 m)
Deck width31 ft (9.4 m)
Roadway width28 ft (8.6 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic68 (2020)
Projected traffic74 by 2040
Trucks—
Lanes on structure2
Traffic directionTwo-way traffic
CarriesHighway
CrossesWaterway
Detour if closed1.2 mi (2 km)
TollOn a free road
National Highway SystemYes

Ownership and planned work

OwnerCity or Municipal Highway Agency
Maintained byCity or Municipal Highway Agency
Historic statusHistorical significance not determinable at this time
Work proposedNone recorded
Estimated improvement cost—
NavigationNo navigation control on waterway

Frequently asked questions

When was Industrial Drive over Cooley Creek built?

It was built in 1995, making it 30 years old in 2025.

What condition is Industrial Drive over Cooley Creek in?

The National Bridge Inventory rates it in fair condition. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. The last reported inspection was in July 2023.

How much traffic does Industrial Drive over Cooley Creek carry?

About 68 vehicles per day (2020 count).

How long is Industrial Drive over Cooley Creek?

The structure is 220 ft (67.1 m) long with a longest span of 20 ft (6.1 m) and a deck 31 ft wide.

Who owns Industrial Drive over Cooley Creek?

It is owned by the City or Municipal Highway Agency.