US Bridges

Chandler RD over I0020

PoorPosted for load

Lincoln Parish, Louisiana · 3.55 MI East of LA 33 · Structure no. 053104510519141

Built
1960
65 years old
Condition
Poor
inspected December 2023
Type
Stringer/Multi-beam or Girder
Steel
Length
307 ft
2 main spans
Daily traffic
3,600
2015 count
Owner
State
State Highway Agency

About this bridge

Chandler RD over I0020 is a steel stringer/multi-beam or girder carrying Chandler RD over I0020 in Lincoln Parish, Louisiana. It was built in 1960, so it is 65 years old, older than the Louisiana average of 43 years.

The most recent inspection reported to the Federal Highway Administration rates it in poor condition with a lowest component rating of 4 out of 9. The lowest-rated primary component is rated 4 or below, indicating advanced deterioration. Poor does not mean unsafe; such bridges are inspected more often and may carry load restrictions. Its operating status is: posted for load restriction.

It carries about 3,600 vehicles a day, projected to reach 3,960 by 2035. The structure is 307 ft (93.6 m) long and 30 ft wide. If it were closed, the detour would be 1.2 mi (2 km).

CarriesChandler RD
CrossesI0020
Location3.55 MI East of LA 33
RouteCounty Highway 0
Coordinates32.53952, -92.5551
Functional classRural Local

Condition and inspection

Poor

The lowest-rated primary component is rated 4 or below, indicating advanced deterioration. Poor does not mean unsafe; such bridges are inspected more often and may carry load restrictions.

ComponentRatingMeaning
Deck5 FairAll primary structural elements are sound but may have minor section loss, cracking, spalling or scour.
Superstructure4 PoorAdvanced section loss, deterioration, spalling or scour.
Substructure6 SatisfactoryStructural elements show some minor deterioration.
Last inspectionDecember 2023
Inspection intervalevery 24 months
Operating statusPosted for load restriction
ScourBridge not over waterway
Structural evaluation4: Meets minimum tolerable limits to be left in place as is
Deck geometry2: Basically intolerable, requiring high priority of replacement
Approach roadway alignment8: Equal to present desirable criteria
Operating rating23.9 US tons
Inventory rating18.2 US tons

Structure

MaterialSteel
DeckConcrete, cast-in-place
Main spans2 (+3 approach)
Design loadH 15
Structure length307 ft (93.6 m)
Longest span75 ft (22.9 m)
Deck width30 ft (9 m)
Roadway width24 ft (7.3 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic3,600 (2015)
Projected traffic3,960 by 2035
Trucks—
Lanes on structure2
Traffic directionTwo-way traffic
CarriesHighway
CrossesHighway
Detour if closed1.2 mi (2 km)
TollOn a free road
National Highway SystemNo

Ownership and planned work

OwnerState Highway Agency
Maintained byState Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedReplacement because of substandard load-carrying capacity or roadway geometry
Estimated improvement cost$1.3 million
NavigationNot applicable (no waterway)

Frequently asked questions

When was Chandler RD over I0020 built?

It was built in 1960, making it 65 years old in 2025.

What condition is Chandler RD over I0020 in?

The National Bridge Inventory rates it in poor condition. The lowest-rated primary component is rated 4 or below, indicating advanced deterioration. Poor does not mean unsafe; such bridges are inspected more often and may carry load restrictions. The last reported inspection was in December 2023.

How much traffic does Chandler RD over I0020 carry?

About 3,600 vehicles per day (2015 count).

How long is Chandler RD over I0020?

The structure is 307 ft (93.6 m) long with a longest span of 75 ft (22.9 m) and a deck 30 ft wide.

Who owns Chandler RD over I0020?

It is owned by the State Highway Agency.