FAP 756 (bridge ST over Sangamon River
GoodPiatt County, Illinois · W Edge of Monticello · Structure no. 074002100000000
- Built
- 1950
- 75 years old, rebuilt 1995
- Condition
- Good
- inspected November 2024
- Type
- Stringer/Multi-beam or Girder
- Steel Continuous
- Length
- 531 ft
- 6 main spans
- Daily traffic
- 5,150
- 2020 count
- Owner
- State
- State Highway Agency
About this bridge
FAP 756 (bridge ST over Sangamon River is a steel continuous stringer/multi-beam or girder carrying FAP 756 (bridge ST over Sangamon River in Piatt County, Illinois. It was built in 1950 and reconstructed in 1995, so it is 75 years old, older than the Illinois average of 45.3 years.
The most recent inspection reported to the Federal Highway Administration rates it in good condition with a lowest component rating of 7 out of 9. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.
It carries about 5,150 vehicles a day, roughly 8% of them trucks, projected to reach 5,202 by 2046. The structure is 531 ft (161.8 m) long and 39 ft wide. If it were closed, the detour would be 1.9 mi (3 km).
Location
Open in Google MapsCondition and inspection
All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.
| Component | Rating | Meaning |
|---|---|---|
| Deck | 7 Good | Some minor problems. |
| Superstructure | 7 Good | Some minor problems. |
| Substructure | 7 Good | Some minor problems. |
| Channel and channel protection | 8 Very Good | No problems noted. |
Structure
Traffic and service
Ownership and planned work
Frequently asked questions
When was FAP 756 (bridge ST over Sangamon River built?
It was built in 1950, making it 75 years old in 2025. It was reconstructed in 1995.
What condition is FAP 756 (bridge ST over Sangamon River in?
The National Bridge Inventory rates it in good condition. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted. The last reported inspection was in November 2024.
How much traffic does FAP 756 (bridge ST over Sangamon River carry?
About 5,150 vehicles per day (2020 count), of which roughly 8% are trucks.
How long is FAP 756 (bridge ST over Sangamon River?
The structure is 531 ft (161.8 m) long with a longest span of 101 ft (30.8 m) and a deck 39 ft wide.
Who owns FAP 756 (bridge ST over Sangamon River?
It is owned by the State Highway Agency.