US Bridges

TR-212A over Seminary Creek

Fair

Clay County, Illinois · 1 MI S Flora · Structure no. 013308800000000

Built
1960
65 years old
Condition
Fair
inspected March 2024
Type
Stringer/Multi-beam or Girder
Steel
Length
30 ft
1 main span
Daily traffic
200
2021 count
Owner
Town / Township
Town or Township Highway Agency

About this bridge

TR-212A over Seminary Creek is a steel stringer/multi-beam or girder carrying TR-212A over Seminary Creek in Clay County, Illinois. It was built in 1960, so it is 65 years old, older than the Illinois average of 45.3 years.

The most recent inspection reported to the Federal Highway Administration rates it in fair condition with a lowest component rating of 5 out of 9. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

It carries about 200 vehicles a day, roughly 2% of them trucks, projected to reach 202 by 2046. The structure is 30 ft (9.1 m) long and 16 ft wide. If it were closed, the detour would be 6.2 mi (10 km).

CarriesTR-212A
CrossesSeminary Creek
Location1 MI S Flora
RouteCounty Highway 0
Coordinates38.64501, -88.46823
Functional classRural Local

Condition and inspection

Fair

The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

ComponentRatingMeaning
Deck5 FairAll primary structural elements are sound but may have minor section loss, cracking, spalling or scour.
Superstructure5 FairAll primary structural elements are sound but may have minor section loss, cracking, spalling or scour.
Substructure5 FairAll primary structural elements are sound but may have minor section loss, cracking, spalling or scour.
Channel and channel protection5 FairAll primary structural elements are sound but may have minor section loss, cracking, spalling or scour.
Last inspectionMarch 2024
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourFoundations stable; scour within limits of footing or piles
Structural evaluation5: Somewhat better than minimum adequacy to tolerate being left in place as is
Deck geometry2: Basically intolerable, requiring high priority of replacement
Waterway adequacy5: Somewhat better than minimum adequacy to tolerate being left in place as is
Approach roadway alignment5: Somewhat better than minimum adequacy to tolerate being left in place as is
Operating rating57.1 US tons
Inventory rating34.3 US tons

Structure

MaterialSteel
DeckConcrete, cast-in-place
Main spans1
Design loadUnknown
Structure length30 ft (9.1 m)
Longest span28 ft (8.5 m)
Deck width16 ft (4.9 m)
Roadway width15 ft (4.6 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic200 (2021)
Projected traffic202 by 2046
Trucks2%
Lanes on structure1
Traffic directionOne-lane bridge for two-way traffic
CarriesHighway
CrossesWaterway
Detour if closed6.2 mi (10 km)
TollOn a free road
National Highway SystemNo

Ownership and planned work

OwnerTown or Township Highway Agency
Maintained byTown or Township Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedReplacement because of substandard load-carrying capacity or roadway geometry
Estimated improvement cost$76,000
NavigationNo navigation control on waterway

Frequently asked questions

When was TR-212A over Seminary Creek built?

It was built in 1960, making it 65 years old in 2025.

What condition is TR-212A over Seminary Creek in?

The National Bridge Inventory rates it in fair condition. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. The last reported inspection was in March 2024.

How much traffic does TR-212A over Seminary Creek carry?

About 200 vehicles per day (2021 count), of which roughly 2% are trucks.

How long is TR-212A over Seminary Creek?

The structure is 30 ft (9.1 m) long with a longest span of 28 ft (8.5 m) and a deck 16 ft wide.

Who owns TR-212A over Seminary Creek?

It is owned by the Town or Township Highway Agency.