US Bridges

E134-FAIR Oaks Ave over N710-E210 Connector

Good

Los Angeles County, California · 07-LA-210-R25.12-PAS · Structure no. 53 2323S

Built
1974
51 years old
Condition
Good
inspected October 2023
Type
Box Beam or Girders - Multiple
Prestressed Concrete Continuous
Length
363 ft
3 main spans
Daily traffic
10,990
2015 count
Owner
State
State Highway Agency

About this bridge

E134-FAIR Oaks Ave over N710-E210 Connector is a prestressed concrete continuous box beam or girders - multiple carrying E134-FAIR Oaks Ave over N710-E210 Connector in Los Angeles County, California. It was built in 1974, so it is 51 years old, younger than the California average of 54.8 years.

The most recent inspection reported to the Federal Highway Administration rates it in good condition with a lowest component rating of 7 out of 9. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

It carries about 10,990 vehicles a day, roughly 2% of them trucks, projected to reach 13,306 by 2042. The structure is 363 ft (110.6 m) long and 26 ft wide. If it were closed, the detour would be 1.2 mi (2 km).

CarriesE134-FAIR Oaks Ave
CrossesN710-E210 Connector
Location07-LA-210-R25.12-PAS
RouteInterstate 210
Coordinates34.15031, -118.15377
Functional classUrban Principal Arterial - Other Freeway or Expressway

Condition and inspection

Good

All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

ComponentRatingMeaning
Deck7 GoodSome minor problems.
Superstructure7 GoodSome minor problems.
Substructure7 GoodSome minor problems.
Last inspectionOctober 2023
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourBridge not over waterway
Structural evaluation7: Better than present minimum criteria
Deck geometry2: Basically intolerable, requiring high priority of replacement
Approach roadway alignment8: Equal to present desirable criteria
Operating rating96.5 US tons
Inventory rating35.7 US tons

Structure

MaterialPrestressed Concrete Continuous
DeckConcrete, cast-in-place
Main spans3
Design loadHS 20
Structure length363 ft (110.6 m)
Longest span174 ft (53 m)
Deck width26 ft (7.9 m)
Roadway width24 ft (7.3 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic10,990 (2015)
Projected traffic13,306 by 2042
Trucks2%
Lanes on structure1
Traffic directionOne-way traffic
CarriesHighway
CrossesHighway
Detour if closed1.2 mi (2 km)
TollOn a free road
National Highway SystemYes
Strategic Highway NetworkNon-Interstate STRAHNET route

Ownership and planned work

OwnerState Highway Agency
Maintained byState Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedNone recorded
Estimated improvement cost—
NavigationNot applicable (no waterway)

Frequently asked questions

When was E134-FAIR Oaks Ave over N710-E210 Connector built?

It was built in 1974, making it 51 years old in 2025.

What condition is E134-FAIR Oaks Ave over N710-E210 Connector in?

The National Bridge Inventory rates it in good condition. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted. The last reported inspection was in October 2023.

How much traffic does E134-FAIR Oaks Ave over N710-E210 Connector carry?

About 10,990 vehicles per day (2015 count), of which roughly 2% are trucks.

How long is E134-FAIR Oaks Ave over N710-E210 Connector?

The structure is 363 ft (110.6 m) long with a longest span of 174 ft (53 m) and a deck 26 ft wide.

Who owns E134-FAIR Oaks Ave over N710-E210 Connector?

It is owned by the State Highway Agency.