US Bridges

Lrd Cortland Ave over IH 94

Fair

Monroe County, Wisconsin · 0.4M E JCT Ush 12 · Structure no. B41006800000000

Built
1968
57 years old
Condition
Fair
inspected October 2024
Type
Stringer/Multi-beam or Girder
Steel Continuous
Length
195 ft
2 main spans
Daily traffic
430
2022 count
Owner
State
State Highway Agency

About this bridge

Lrd Cortland Ave over IH 94 is a steel continuous stringer/multi-beam or girder carrying Lrd Cortland Ave over IH 94 in Monroe County, Wisconsin. It was built in 1968, so it is 57 years old, older than the Wisconsin average of 40.3 years.

The most recent inspection reported to the Federal Highway Administration rates it in fair condition with a lowest component rating of 6 out of 9. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

It carries about 430 vehicles a day, projected to reach 275 by 2043. The structure is 195 ft (59.4 m) long and 31 ft wide. If it were closed, the detour would be 7.5 mi (12 km).

CarriesLrd Cortland Ave
CrossesIH 94
Location0.4M E JCT Ush 12
RouteCity Street 0
Coordinates44.09479, -90.53294
Functional classRural Local

Condition and inspection

Fair

The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

ComponentRatingMeaning
Deck7 GoodSome minor problems.
Superstructure6 SatisfactoryStructural elements show some minor deterioration.
Substructure6 SatisfactoryStructural elements show some minor deterioration.
Last inspectionOctober 2024
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourBridge not over waterway
Structural evaluation5: Somewhat better than minimum adequacy to tolerate being left in place as is
Deck geometry5: Somewhat better than minimum adequacy to tolerate being left in place as is
Approach roadway alignment8: Equal to present desirable criteria
Operating rating43.2 US tons
Inventory rating21.4 US tons

Structure

MaterialSteel Continuous
DeckConcrete, cast-in-place
Main spans2
Design loadH 15
Structure length195 ft (59.4 m)
Longest span95 ft (29.1 m)
Deck width31 ft (9.3 m)
Roadway width27 ft (8.2 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic430 (2022)
Projected traffic275 by 2043
Trucks0%
Lanes on structure2
Traffic directionTwo-way traffic
CarriesHighway
CrossesHighway
Detour if closed7.5 mi (12 km)
TollOn a free road
National Highway SystemNo

Ownership and planned work

OwnerState Highway Agency
Maintained byState Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedNone recorded
Estimated improvement cost—
NavigationNot applicable (no waterway)

Frequently asked questions

When was Lrd Cortland Ave over IH 94 built?

It was built in 1968, making it 57 years old in 2025.

What condition is Lrd Cortland Ave over IH 94 in?

The National Bridge Inventory rates it in fair condition. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. The last reported inspection was in October 2024.

How much traffic does Lrd Cortland Ave over IH 94 carry?

About 430 vehicles per day (2022 count).

How long is Lrd Cortland Ave over IH 94?

The structure is 195 ft (59.4 m) long with a longest span of 95 ft (29.1 m) and a deck 31 ft wide.

Who owns Lrd Cortland Ave over IH 94?

It is owned by the State Highway Agency.