IH 94 Eb-Stadium I over Sth 175 Nb-Stadium Intch
FairMilwaukee County, Wisconsin · 2.6M E JCT Sth 181 · Structure no. B40004100000000
- Built
- 1959
- 66 years old
- Condition
- Fair
- inspected June 2024
- Type
- Stringer/Multi-beam or Girder
- Steel Continuous
- Length
- 115 ft
- 3 main spans
- Daily traffic
- 79,500
- 2022 count
- Owner
- State
- State Highway Agency
About this bridge
IH 94 Eb-Stadium I over Sth 175 Nb-Stadium Intch is a steel continuous stringer/multi-beam or girder carrying IH 94 Eb-Stadium I over Sth 175 Nb-Stadium Intch in Milwaukee County, Wisconsin. It was built in 1959, so it is 66 years old, older than the Wisconsin average of 40.3 years.
The most recent inspection reported to the Federal Highway Administration rates it in fair condition with a lowest component rating of 5 out of 9. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.
It carries about 79,500 vehicles a day, roughly 1% of them trucks, projected to reach 95,400 by 2042. The structure is 115 ft (35 m) long and 59 ft wide. If it were closed, the detour would be 0.6 mi (1 km).
Location
Open in Google MapsCondition and inspection
The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.
| Component | Rating | Meaning |
|---|---|---|
| Deck | 7 Good | Some minor problems. |
| Superstructure | 5 Fair | All primary structural elements are sound but may have minor section loss, cracking, spalling or scour. |
| Substructure | 6 Satisfactory | Structural elements show some minor deterioration. |
Structure
Traffic and service
Ownership and planned work
Frequently asked questions
When was IH 94 Eb-Stadium I over Sth 175 Nb-Stadium Intch built?
It was built in 1959, making it 66 years old in 2025.
What condition is IH 94 Eb-Stadium I over Sth 175 Nb-Stadium Intch in?
The National Bridge Inventory rates it in fair condition. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. The last reported inspection was in June 2024.
How much traffic does IH 94 Eb-Stadium I over Sth 175 Nb-Stadium Intch carry?
About 79,500 vehicles per day (2022 count), of which roughly 1% are trucks.
How long is IH 94 Eb-Stadium I over Sth 175 Nb-Stadium Intch?
The structure is 115 ft (35 m) long with a longest span of 48 ft (14.6 m) and a deck 59 ft wide.
Who owns IH 94 Eb-Stadium I over Sth 175 Nb-Stadium Intch?
It is owned by the State Highway Agency.