US Bridges

Genoa RD over Turner Run

Good

Rockingham County, Virginia · 0.20 Rt 815 - 3.10 Rt 612 · Structure no. 000000000025494

Built
1998
27 years old
Condition
Good
inspected September 2024
Type
Box Beam or Girders - Multiple
Prestressed Concrete
Length
52 ft
1 main span
Daily traffic
136
2018 count
Owner
State
State Highway Agency

About this bridge

Genoa RD over Turner Run is a prestressed concrete box beam or girders - multiple carrying Genoa RD over Turner Run in Rockingham County, Virginia. It was built in 1998, so it is 27 years old, younger than the Virginia average of 50.7 years.

The most recent inspection reported to the Federal Highway Administration rates it in good condition with a lowest component rating of 7 out of 9. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

It carries about 136 vehicles a day, projected to reach 209 by 2042. The structure is 52 ft (15.9 m) long and 28 ft wide. If it were closed, the detour would be 1.9 mi (3 km).

CarriesGenoa RD
CrossesTurner Run
Location0.20 Rt 815 - 3.10 Rt 612
RouteCounty Highway 817
Coordinates38.63875, -78.92981
Functional classRural Local

Condition and inspection

Good

All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

ComponentRatingMeaning
Deck7 GoodSome minor problems.
Superstructure7 GoodSome minor problems.
Substructure8 Very GoodNo problems noted.
Channel and channel protection8 Very GoodNo problems noted.
Last inspectionSeptember 2024
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourFoundations stable; scour above top of footing
Structural evaluation7: Better than present minimum criteria
Deck geometry5: Somewhat better than minimum adequacy to tolerate being left in place as is
Waterway adequacy5: Somewhat better than minimum adequacy to tolerate being left in place as is
Approach roadway alignment7: Better than present minimum criteria
Operating rating103.9 US tons
Inventory rating80 US tons

Structure

MaterialPrestressed Concrete
DeckOther
Main spans1
Design loadHS 20 + Mod
Structure length52 ft (15.9 m)
Longest span52 ft (15.9 m)
Deck width28 ft (8.5 m)
Roadway width25 ft (7.5 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic136 (2018)
Projected traffic209 by 2042
Trucks0%
Lanes on structure2
Traffic directionTwo-way traffic
CarriesHighway
CrossesWaterway
Detour if closed1.9 mi (3 km)
TollOn a free road
National Highway SystemNo

Ownership and planned work

OwnerState Highway Agency
Maintained byState Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedNone recorded
Estimated improvement cost—
NavigationNo navigation control on waterway

Frequently asked questions

When was Genoa RD over Turner Run built?

It was built in 1998, making it 27 years old in 2025.

What condition is Genoa RD over Turner Run in?

The National Bridge Inventory rates it in good condition. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted. The last reported inspection was in September 2024.

How much traffic does Genoa RD over Turner Run carry?

About 136 vehicles per day (2018 count).

How long is Genoa RD over Turner Run?

The structure is 52 ft (15.9 m) long with a longest span of 52 ft (15.9 m) and a deck 28 ft wide.

Who owns Genoa RD over Turner Run?

It is owned by the State Highway Agency.