US Bridges

FM 1300 over Sandy Creek

Good

Wharton County, Texas · 6.35 MI W of FM 1160 · Structure no. 132410042010014

Built
1976
49 years old
Condition
Good
inspected November 2024
Type
Stringer/Multi-beam or Girder
Prestressed Concrete
Length
1,052 ft
1 main span
Daily traffic
275
2024 count
Owner
State
State Highway Agency

About this bridge

FM 1300 over Sandy Creek is a prestressed concrete stringer/multi-beam or girder carrying FM 1300 over Sandy Creek in Wharton County, Texas. It was built in 1976, so it is 49 years old, older than the Texas average of 44.4 years.

The most recent inspection reported to the Federal Highway Administration rates it in good condition with a lowest component rating of 7 out of 9. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

It carries about 275 vehicles a day, roughly 4% of them trucks, projected to reach 490 by 2033. The structure is 1,052 ft (320.7 m) long and 36 ft wide. If it were closed, the detour would be 24.2 mi (39 km).

CarriesFM 1300
CrossesSandy Creek
Location6.35 MI W of FM 1160
RouteState Highway 1300
StateTexas
Coordinates29.23376, -96.5
Functional classRural Major Collector

Condition and inspection

Good

All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

ComponentRatingMeaning
Deck7 GoodSome minor problems.
Superstructure7 GoodSome minor problems.
Substructure7 GoodSome minor problems.
Channel and channel protection7 GoodSome minor problems.
Last inspectionNovember 2024
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourFoundations stable; scour above top of footing
Structural evaluation7: Better than present minimum criteria
Deck geometry7: Better than present minimum criteria
Waterway adequacy6: Equal to present minimum criteria
Approach roadway alignment7: Better than present minimum criteria
Operating rating60 US tons
Inventory rating36 US tons

Structure

MaterialPrestressed Concrete
DeckConcrete, cast-in-place
Main spans1 (+25 approach)
Design loadHS 20
Structure length1,052 ft (320.7 m)
Longest span100 ft (30.5 m)
Deck width36 ft (11 m)
Roadway width34 ft (10.4 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic275 (2024)
Projected traffic490 by 2033
Trucks4%
Lanes on structure2
Traffic directionTwo-way traffic
CarriesHighway
CrossesWaterway
Detour if closed24.2 mi (39 km)
TollOn a free road
National Highway SystemNo

Ownership and planned work

OwnerState Highway Agency
Maintained byState Highway Agency
Historic statusPossibly eligible for the National Register; requires further investigation
Work proposedNone recorded
Estimated improvement cost—
NavigationNo navigation control on waterway

Frequently asked questions

When was FM 1300 over Sandy Creek built?

It was built in 1976, making it 49 years old in 2025.

What condition is FM 1300 over Sandy Creek in?

The National Bridge Inventory rates it in good condition. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted. The last reported inspection was in November 2024.

How much traffic does FM 1300 over Sandy Creek carry?

About 275 vehicles per day (2024 count), of which roughly 4% are trucks.

How long is FM 1300 over Sandy Creek?

The structure is 1,052 ft (320.7 m) long with a longest span of 100 ft (30.5 m) and a deck 36 ft wide.

Who owns FM 1300 over Sandy Creek?

It is owned by the State Highway Agency.