US Bridges

E Ramp from Garage over Open Ground

Fair

Travis County, Texas · 0.07 MI W of Presidential · Structure no. 142270BA5845002

Built
1999
26 years old
Condition
Fair
inspected June 2024
Type
Box Beam or Girders - Multiple
Prestressed Concrete
Length
224 ft
5 main spans
Daily traffic
3,300
2010 count
Owner
City
City or Municipal Highway Agency

About this bridge

E Ramp from Garage over Open Ground is a prestressed concrete box beam or girders - multiple carrying E Ramp from Garage over Open Ground in Travis County, Texas. It was built in 1999, so it is 26 years old, younger than the Texas average of 44.4 years.

The most recent inspection reported to the Federal Highway Administration rates it in fair condition with a lowest component rating of 6 out of 9. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

It carries about 3,300 vehicles a day, projected to reach 3,900 by 2032. The structure is 224 ft (68.3 m) long and 29 ft wide. If it were closed, the detour would be 1.2 mi (2 km).

CarriesE Ramp from Garage
CrossesOpen Ground
Location0.07 MI W of Presidential
RouteCity Street 0
StateTexas
Coordinates30.20409, -97.66577
Functional classUrban Local

Condition and inspection

Fair

The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

ComponentRatingMeaning
Deck6 SatisfactoryStructural elements show some minor deterioration.
Superstructure7 GoodSome minor problems.
Substructure6 SatisfactoryStructural elements show some minor deterioration.
Last inspectionJune 2024
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourBridge not over waterway
Structural evaluation6: Equal to present minimum criteria
Deck geometry2: Basically intolerable, requiring high priority of replacement
Approach roadway alignment8: Equal to present desirable criteria
Operating rating60 US tons
Inventory rating36 US tons

Structure

MaterialPrestressed Concrete
DeckConcrete, cast-in-place
Main spans5 (+1 approach)
Design loadHS 20
Structure length224 ft (68.3 m)
Longest span40 ft (12.2 m)
Deck width29 ft (8.8 m)
Roadway width24 ft (7.3 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic3,300 (2010)
Projected traffic3,900 by 2032
Trucks0%
Lanes on structure1
Traffic directionOne-way traffic
CarriesHighway
CrossesOther
Detour if closed1.2 mi (2 km)
TollOn a free road
National Highway SystemNo

Ownership and planned work

OwnerCity or Municipal Highway Agency
Maintained byCity or Municipal Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedNone recorded
Estimated improvement cost—
NavigationNo navigation control on waterway

Frequently asked questions

When was E Ramp from Garage over Open Ground built?

It was built in 1999, making it 26 years old in 2025.

What condition is E Ramp from Garage over Open Ground in?

The National Bridge Inventory rates it in fair condition. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. The last reported inspection was in June 2024.

How much traffic does E Ramp from Garage over Open Ground carry?

About 3,300 vehicles per day (2010 count).

How long is E Ramp from Garage over Open Ground?

The structure is 224 ft (68.3 m) long with a longest span of 40 ft (12.2 m) and a deck 29 ft wide.

Who owns E Ramp from Garage over Open Ground?

It is owned by the City or Municipal Highway Agency.