E Seminary DR EB over Sycamore Creek
FairTarrant County, Texas · 0.86 MI E IH 35 N IH 20 · Structure no. 022200ZS2737002
- Built
- 1962
- 63 years old
- Condition
- Fair
- inspected March 2024
- Type
- Stringer/Multi-beam or Girder
- Steel Continuous
- Length
- 193 ft
- 3 main spans
- Daily traffic
- 16,435
- 2016 count
- Owner
- City
- City or Municipal Highway Agency
About this bridge
E Seminary DR EB over Sycamore Creek is a steel continuous stringer/multi-beam or girder carrying E Seminary DR EB over Sycamore Creek in Tarrant County, Texas. It was built in 1962, so it is 63 years old, older than the Texas average of 44.4 years.
The most recent inspection reported to the Federal Highway Administration rates it in fair condition with a lowest component rating of 6 out of 9. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.
It carries about 16,435 vehicles a day, roughly 10% of them trucks, projected to reach 16,485 by 2036. The structure is 193 ft (58.9 m) long and 41 ft wide. If it were closed, the detour would be 3.1 mi (5 km).
Location
Open in Google MapsCondition and inspection
The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.
| Component | Rating | Meaning |
|---|---|---|
| Deck | 6 Satisfactory | Structural elements show some minor deterioration. |
| Superstructure | 7 Good | Some minor problems. |
| Substructure | 6 Satisfactory | Structural elements show some minor deterioration. |
| Channel and channel protection | 7 Good | Some minor problems. |
Structure
Traffic and service
Ownership and planned work
Frequently asked questions
When was E Seminary DR EB over Sycamore Creek built?
It was built in 1962, making it 63 years old in 2025.
What condition is E Seminary DR EB over Sycamore Creek in?
The National Bridge Inventory rates it in fair condition. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. The last reported inspection was in March 2024.
How much traffic does E Seminary DR EB over Sycamore Creek carry?
About 16,435 vehicles per day (2016 count), of which roughly 10% are trucks.
How long is E Seminary DR EB over Sycamore Creek?
The structure is 193 ft (58.9 m) long with a longest span of 50 ft (15.2 m) and a deck 41 ft wide.
Who owns E Seminary DR EB over Sycamore Creek?
It is owned by the City or Municipal Highway Agency.