US Bridges

Terminal B Rp 5-2W over Terminal B Recirculation

Fair

Tarrant County, Texas · 0.1 MI S of Trm B X-Under · Structure no. 022200BB0985129

Built
1974
51 years old
Condition
Fair
inspected May 2024
Type
Box Beam or Girders - Single or Spread
Steel
Length
106 ft
1 main span
Daily traffic
2,500
2016 count
Owner
Local
Other Local Agency

About this bridge

Terminal B Rp 5-2W over Terminal B Recirculation is a steel box beam or girders - single or spread carrying Terminal B Rp 5-2W over Terminal B Recirculation in Tarrant County, Texas. It was built in 1974, so it is 51 years old, older than the Texas average of 44.4 years.

The most recent inspection reported to the Federal Highway Administration rates it in fair condition with a lowest component rating of 6 out of 9. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

It carries about 2,500 vehicles a day, roughly 2% of them trucks, projected to reach 3,000 by 2040. The structure is 106 ft (32.4 m) long and 24 ft wide. If it were closed, the detour would be 1.2 mi (2 km).

CarriesTerminal B Rp 5-2W
CrossesTerminal B Recirculation
Location0.1 MI S of Trm B X-Under
StateTexas
Coordinates32.90377, -97.0419
Functional classUrban Local

Condition and inspection

Fair

The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

ComponentRatingMeaning
Deck7 GoodSome minor problems.
Superstructure7 GoodSome minor problems.
Substructure6 SatisfactoryStructural elements show some minor deterioration.
Last inspectionMay 2024
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourBridge not over waterway
Structural evaluation6: Equal to present minimum criteria
Deck geometry2: Basically intolerable, requiring high priority of replacement
Approach roadway alignment8: Equal to present desirable criteria
Operating rating70 US tons
Inventory rating42 US tons

Structure

MaterialSteel
DeckConcrete, cast-in-place
Main spans1
Design loadHS 20
Structure length106 ft (32.4 m)
Longest span105 ft (32.1 m)
Deck width24 ft (7.4 m)
Roadway width14 ft (4.3 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic2,500 (2016)
Projected traffic3,000 by 2040
Trucks2%
Lanes on structure1
Traffic directionOne-way traffic
CarriesHighway
CrossesHighway
Detour if closed1.2 mi (2 km)
TollOn a free road
National Highway SystemNo

Ownership and planned work

OwnerOther Local Agency
Maintained byOther Local Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedNone recorded
Estimated improvement cost—
NavigationNot applicable (no waterway)

Frequently asked questions

When was Terminal B Rp 5-2W over Terminal B Recirculation built?

It was built in 1974, making it 51 years old in 2025.

What condition is Terminal B Rp 5-2W over Terminal B Recirculation in?

The National Bridge Inventory rates it in fair condition. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. The last reported inspection was in May 2024.

How much traffic does Terminal B Rp 5-2W over Terminal B Recirculation carry?

About 2,500 vehicles per day (2016 count), of which roughly 2% are trucks.

How long is Terminal B Rp 5-2W over Terminal B Recirculation?

The structure is 106 ft (32.4 m) long with a longest span of 105 ft (32.1 m) and a deck 24 ft wide.

Who owns Terminal B Rp 5-2W over Terminal B Recirculation?

It is owned by the Other Local Agency.