US Bridges

IH 30 Ramp 287W over IH 35W Main Lns

Fair

Tarrant County, Texas · .1 MI E of IH 35 · Structure no. 022200106801482

Built
2000
25 years old
Condition
Fair
inspected August 2023
Type
Stringer/Multi-beam or Girder
Prestressed Concrete
Length
652 ft
6 main spans
Daily traffic
21,570
2009 count
Owner
State
State Highway Agency

About this bridge

IH 30 Ramp 287W over IH 35W Main Lns is a prestressed concrete stringer/multi-beam or girder carrying IH 30 Ramp 287W over IH 35W Main Lns in Tarrant County, Texas. It was built in 2000, so it is 25 years old, younger than the Texas average of 44.4 years.

The most recent inspection reported to the Federal Highway Administration rates it in fair condition with a lowest component rating of 6 out of 9. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

It carries about 21,570 vehicles a day, roughly 10% of them trucks, projected to reach 21,890 by 2029. The structure is 652 ft (198.7 m) long and 26 ft wide. If it were closed, the detour would be 1.2 mi (2 km).

CarriesIH 30 Ramp 287W
CrossesIH 35W Main Lns
Location.1 MI E of IH 35
RouteInterstate 30
StateTexas
Coordinates32.74752, -97.31831
Functional classUrban Principal Arterial - Interstate

Condition and inspection

Fair

The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

ComponentRatingMeaning
Deck7 GoodSome minor problems.
Superstructure6 SatisfactoryStructural elements show some minor deterioration.
Substructure7 GoodSome minor problems.
Last inspectionAugust 2023
Inspection intervalevery 48 months
Operating statusOpen, no restriction
ScourBridge not over waterway
Structural evaluation6: Equal to present minimum criteria
Deck geometry6: Equal to present minimum criteria
Approach roadway alignment8: Equal to present desirable criteria
Operating rating60 US tons
Inventory rating36 US tons

Structure

MaterialPrestressed Concrete
DeckConcrete, cast-in-place
Main spans6
Design loadHS 20
Structure length652 ft (198.7 m)
Longest span117 ft (35.7 m)
Deck width26 ft (7.9 m)
Roadway width24 ft (7.3 m)
Vertical clearance over deck17 ft (5 m)

Traffic and service

Average daily traffic21,570 (2009)
Projected traffic21,890 by 2029
Trucks10%
Lanes on structure1
Traffic directionOne-way traffic
CarriesOverpass structure at an interchange
CrossesHighway
Detour if closed1.2 mi (2 km)
TollOn a free road
National Highway SystemYes
Strategic Highway NetworkNon-Interstate STRAHNET route

Ownership and planned work

OwnerState Highway Agency
Maintained byState Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedNone recorded
Estimated improvement cost—
NavigationNot applicable (no waterway)

Frequently asked questions

When was IH 30 Ramp 287W over IH 35W Main Lns built?

It was built in 2000, making it 25 years old in 2025.

What condition is IH 30 Ramp 287W over IH 35W Main Lns in?

The National Bridge Inventory rates it in fair condition. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. The last reported inspection was in August 2023.

How much traffic does IH 30 Ramp 287W over IH 35W Main Lns carry?

About 21,570 vehicles per day (2009 count), of which roughly 10% are trucks.

How long is IH 30 Ramp 287W over IH 35W Main Lns?

The structure is 652 ft (198.7 m) long with a longest span of 117 ft (35.7 m) and a deck 26 ft wide.

Who owns IH 30 Ramp 287W over IH 35W Main Lns?

It is owned by the State Highway Agency.