US Bridges

US 81/US 287 SB over BNSF Railroad

Good

Tarrant County, Texas · 1.1 MI NW of FM 156 · Structure no. 022200001415385

Built
1976
49 years old, rebuilt 1996
Condition
Good
inspected August 2023
Type
Stringer/Multi-beam or Girder
Prestressed Concrete
Length
302 ft
4 main spans
Daily traffic
22,913
2020 count
Owner
State
State Highway Agency

About this bridge

US 81/US 287 SB over BNSF Railroad is a prestressed concrete stringer/multi-beam or girder carrying US 81/US 287 SB over BNSF Railroad in Tarrant County, Texas. It was built in 1976 and reconstructed in 1996, so it is 49 years old, older than the Texas average of 44.4 years.

The most recent inspection reported to the Federal Highway Administration rates it in good condition with a lowest component rating of 7 out of 9. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

It carries about 22,913 vehicles a day, roughly 17% of them trucks, projected to reach 25,090 by 2035. The structure is 302 ft (92.1 m) long and 44 ft wide. If it were closed, the detour would be 1.2 mi (2 km).

CarriesUS 81/US 287 SB
CrossesBNSF Railroad
Location1.1 MI NW of FM 156
RouteU.S. Route 81
StateTexas
Coordinates32.92722, -97.36126
Functional classUrban Principal Arterial - Other Freeway or Expressway

Condition and inspection

Good

All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

ComponentRatingMeaning
Deck7 GoodSome minor problems.
Superstructure7 GoodSome minor problems.
Substructure7 GoodSome minor problems.
Last inspectionAugust 2023
Inspection intervalevery 48 months
Operating statusOpen, no restriction
ScourBridge not over waterway
Structural evaluation7: Better than present minimum criteria
Deck geometry7: Better than present minimum criteria
Approach roadway alignment8: Equal to present desirable criteria
Operating rating60 US tons
Inventory rating36 US tons

Structure

MaterialPrestressed Concrete
DeckConcrete, cast-in-place
Main spans4
Design loadHS 20
Structure length302 ft (92.1 m)
Longest span78 ft (23.8 m)
Deck width44 ft (13.4 m)
Roadway width41 ft (12.6 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic22,913 (2020)
Projected traffic25,090 by 2035
Trucks17%
Lanes on structure2
Traffic directionOne-way traffic
CarriesHighway
CrossesRailroad
Detour if closed1.2 mi (2 km)
TollOn a free road
National Highway SystemYes
Strategic Highway NetworkNon-Interstate STRAHNET route

Ownership and planned work

OwnerState Highway Agency
Maintained byState Highway Agency
Historic statusPossibly eligible for the National Register; requires further investigation
Work proposedNone recorded
Estimated improvement cost—
NavigationNot applicable (no waterway)

Frequently asked questions

When was US 81/US 287 SB over BNSF Railroad built?

It was built in 1976, making it 49 years old in 2025. It was reconstructed in 1996.

What condition is US 81/US 287 SB over BNSF Railroad in?

The National Bridge Inventory rates it in good condition. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted. The last reported inspection was in August 2023.

How much traffic does US 81/US 287 SB over BNSF Railroad carry?

About 22,913 vehicles per day (2020 count), of which roughly 17% are trucks.

How long is US 81/US 287 SB over BNSF Railroad?

The structure is 302 ft (92.1 m) long with a longest span of 78 ft (23.8 m) and a deck 44 ft wide.

Who owns US 81/US 287 SB over BNSF Railroad?

It is owned by the State Highway Agency.