IH 40 EB over Coulter St.
GoodPotter County, Texas · 1.0 MI E of Lp 335 W · Structure no. 041880027501076
- Built
- 1969
- 56 years old
- Condition
- Good
- inspected July 2023
- Type
- Stringer/Multi-beam or Girder
- Prestressed Concrete
- Length
- 208 ft
- 3 main spans
- Daily traffic
- 33,950
- 2013 count
- Owner
- State
- State Highway Agency
About this bridge
IH 40 EB over Coulter St. is a prestressed concrete stringer/multi-beam or girder carrying IH 40 EB over Coulter St. in Potter County, Texas. It was built in 1969, so it is 56 years old, older than the Texas average of 44.4 years.
The most recent inspection reported to the Federal Highway Administration rates it in good condition with a lowest component rating of 7 out of 9. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.
It carries about 33,950 vehicles a day, roughly 10% of them trucks, projected to reach 47,530 by 2033. The structure is 208 ft (63.4 m) long and 59 ft wide.
Location
Open in Google MapsCondition and inspection
All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.
| Component | Rating | Meaning |
|---|---|---|
| Deck | 8 Very Good | No problems noted. |
| Superstructure | 8 Very Good | No problems noted. |
| Substructure | 7 Good | Some minor problems. |
Structure
Traffic and service
Ownership and planned work
Frequently asked questions
When was IH 40 EB over Coulter St. built?
It was built in 1969, making it 56 years old in 2025.
What condition is IH 40 EB over Coulter St. in?
The National Bridge Inventory rates it in good condition. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted. The last reported inspection was in July 2023.
How much traffic does IH 40 EB over Coulter St. carry?
About 33,950 vehicles per day (2013 count), of which roughly 10% are trucks.
How long is IH 40 EB over Coulter St.?
The structure is 208 ft (63.4 m) long with a longest span of 78 ft (23.8 m) and a deck 59 ft wide.
Who owns IH 40 EB over Coulter St.?
It is owned by the State Highway Agency.