W First ST over Drainage Ditch
FairPosted for loadFort Bend County, Texas · 0.40 MI NW of FM 1236 · Structure no. 120800F00325001
- Built
- 1988
- 37 years old
- Condition
- Fair
- inspected August 2023
- Type
- Stringer/Multi-beam or Girder
- Wood or Timber
- Length
- 30 ft
- 2 main spans
- Daily traffic
- 20
- 2010 count
- Owner
- Town / Township
- Town or Township Highway Agency
About this bridge
W First ST over Drainage Ditch is a wood or timber stringer/multi-beam or girder carrying W First ST over Drainage Ditch in Fort Bend County, Texas. It was built in 1988, so it is 37 years old, younger than the Texas average of 44.4 years.
The most recent inspection reported to the Federal Highway Administration rates it in fair condition with a lowest component rating of 5 out of 9. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. Its operating status is: posted for load restriction.
It carries about 20 vehicles a day, projected to reach 20 by 2030. The structure is 30 ft (9.1 m) long and 24 ft wide. If it were closed, the detour would be 98.8 mi (159 km).
Location
Open in Google MapsCondition and inspection
The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.
| Component | Rating | Meaning |
|---|---|---|
| Deck | 7 Good | Some minor problems. |
| Superstructure | 7 Good | Some minor problems. |
| Substructure | 5 Fair | All primary structural elements are sound but may have minor section loss, cracking, spalling or scour. |
| Channel and channel protection | 7 Good | Some minor problems. |
Structure
Traffic and service
Ownership and planned work
Frequently asked questions
When was W First ST over Drainage Ditch built?
It was built in 1988, making it 37 years old in 2025.
What condition is W First ST over Drainage Ditch in?
The National Bridge Inventory rates it in fair condition. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. The last reported inspection was in August 2023.
How much traffic does W First ST over Drainage Ditch carry?
About 20 vehicles per day (2010 count).
How long is W First ST over Drainage Ditch?
The structure is 30 ft (9.1 m) long with a longest span of 14 ft (4.3 m) and a deck 24 ft wide.
Who owns W First ST over Drainage Ditch?
It is owned by the Town or Township Highway Agency.