US Bridges

IH 10 WB over Hawkins DR

Fair

El Paso County, Texas · 2.9 MI E of US 62 · Structure no. 240720212103236

Built
1989
36 years old, rebuilt 2019
Condition
Fair
inspected July 2023
Type
Box Beam or Girders - Multiple
Prestressed Concrete
Length
200 ft
1 main span
Daily traffic
65,670
2017 count
Owner
State
State Highway Agency

About this bridge

IH 10 WB over Hawkins DR is a prestressed concrete box beam or girders - multiple carrying IH 10 WB over Hawkins DR in El Paso County, Texas. It was built in 1989 and reconstructed in 2019, so it is 36 years old, younger than the Texas average of 44.4 years.

The most recent inspection reported to the Federal Highway Administration rates it in fair condition with a lowest component rating of 6 out of 9. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

It carries about 65,670 vehicles a day, roughly 8% of them trucks, projected to reach 132,970 by 2033. The structure is 200 ft (61 m) long and 82 ft wide.

CarriesIH 10 WB
CrossesHawkins DR
Location2.9 MI E of US 62
RouteInterstate 10
StateTexas
Coordinates31.77156, -106.37719
Functional classUrban Principal Arterial - Interstate

Condition and inspection

Fair

The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

ComponentRatingMeaning
Deck6 SatisfactoryStructural elements show some minor deterioration.
Superstructure7 GoodSome minor problems.
Substructure6 SatisfactoryStructural elements show some minor deterioration.
Last inspectionJuly 2023
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourBridge not over waterway
Structural evaluation6: Equal to present minimum criteria
Deck geometry6: Equal to present minimum criteria
Approach roadway alignment8: Equal to present desirable criteria
Operating rating60 US tons
Inventory rating36 US tons

Structure

MaterialPrestressed Concrete
DeckOther
Main spans1 (+2 approach)
Design loadHS 20
Structure length200 ft (61 m)
Longest span85 ft (25.9 m)
Deck width82 ft (25.1 m)
Roadway width80 ft (24.4 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic65,670 (2017)
Projected traffic132,970 by 2033
Trucks8%
Lanes on structure5
Traffic directionOne-way traffic
CarriesHighway
CrossesHighway
Detour if closed—
TollOn a free road
National Highway SystemYes
Strategic Highway NetworkInterstate STRAHNET route

Ownership and planned work

OwnerState Highway Agency
Maintained byState Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedOther structural work, including hydraulic replacements
Estimated improvement cost$35,000
NavigationNot applicable (no waterway)

Frequently asked questions

When was IH 10 WB over Hawkins DR built?

It was built in 1989, making it 36 years old in 2025. It was reconstructed in 2019.

What condition is IH 10 WB over Hawkins DR in?

The National Bridge Inventory rates it in fair condition. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. The last reported inspection was in July 2023.

How much traffic does IH 10 WB over Hawkins DR carry?

About 65,670 vehicles per day (2017 count), of which roughly 8% are trucks.

How long is IH 10 WB over Hawkins DR?

The structure is 200 ft (61 m) long with a longest span of 85 ft (25.9 m) and a deck 82 ft wide.

Who owns IH 10 WB over Hawkins DR?

It is owned by the State Highway Agency.