US Bridges

3rd ST over Keller Branch

Good

Dallas County, Texas · 0.2 MI W of Hutchins RD · Structure no. 180570M01230002

Built
2020
5 years old
Condition
Good
inspected February 2024
Type
Stringer/Multi-beam or Girder
Prestressed Concrete
Length
140 ft
2 main spans
Daily traffic
500
2018 count
Owner
City
City or Municipal Highway Agency

About this bridge

3rd ST over Keller Branch is a prestressed concrete stringer/multi-beam or girder carrying 3rd ST over Keller Branch in Dallas County, Texas. It was built in 2020, so it is 5 years old, younger than the Texas average of 44.4 years.

The most recent inspection reported to the Federal Highway Administration rates it in good condition with a lowest component rating of 8 out of 9. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

It carries about 500 vehicles a day, projected to reach 1,000 by 2031. The structure is 140 ft (42.7 m) long and 30 ft wide. If it were closed, the detour would be 1.2 mi (2 km).

Carries3rd ST
CrossesKeller Branch
Location0.2 MI W of Hutchins RD
RouteCity Street 0
StateTexas
Coordinates32.59525, -96.75069
Functional classUrban Local

Condition and inspection

Good

All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

ComponentRatingMeaning
Deck8 Very GoodNo problems noted.
Superstructure8 Very GoodNo problems noted.
Substructure8 Very GoodNo problems noted.
Channel and channel protection7 GoodSome minor problems.
Last inspectionFebruary 2024
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourFoundations stable; scour above top of footing
Structural evaluation8: Equal to present desirable criteria
Deck geometry5: Somewhat better than minimum adequacy to tolerate being left in place as is
Waterway adequacy8: Equal to present desirable criteria
Approach roadway alignment7: Better than present minimum criteria
Operating rating60 US tons
Inventory rating36 US tons

Structure

MaterialPrestressed Concrete
DeckConcrete, cast-in-place
Main spans2
Design loadHL 93
Structure length140 ft (42.7 m)
Longest span85 ft (25.9 m)
Deck width30 ft (9.1 m)
Roadway width28 ft (8.4 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic500 (2018)
Projected traffic1,000 by 2031
Trucks0%
Lanes on structure2
Traffic directionTwo-way traffic
CarriesHighway
CrossesWaterway
Detour if closed1.2 mi (2 km)
TollOn a free road
National Highway SystemNo

Ownership and planned work

OwnerCity or Municipal Highway Agency
Maintained byCity or Municipal Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedNone recorded
Estimated improvement cost—
NavigationNot applicable (no waterway)

Frequently asked questions

When was 3rd ST over Keller Branch built?

It was built in 2020, making it 5 years old in 2025.

What condition is 3rd ST over Keller Branch in?

The National Bridge Inventory rates it in good condition. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted. The last reported inspection was in February 2024.

How much traffic does 3rd ST over Keller Branch carry?

About 500 vehicles per day (2018 count).

How long is 3rd ST over Keller Branch?

The structure is 140 ft (42.7 m) long with a longest span of 85 ft (25.9 m) and a deck 30 ft wide.

Who owns 3rd ST over Keller Branch?

It is owned by the City or Municipal Highway Agency.