US Bridges

SH 183 Eb-Sp 482NB over SH 183 & SP 482 SB

Good

Dallas County, Texas · 0.2 MI E of Loop 12 · Structure no. 180570009407354

Built
2024
1 years old
Condition
Good
inspected May 2024
Type
Stringer/Multi-beam or Girder
Prestressed Concrete
Length
1,399 ft
12 main spans
Daily traffic
155,355
2022 count
Owner
State
State Highway Agency

About this bridge

SH 183 Eb-Sp 482NB over SH 183 & SP 482 SB is a prestressed concrete stringer/multi-beam or girder carrying SH 183 Eb-Sp 482NB over SH 183 & SP 482 SB in Dallas County, Texas. It was built in 2024, so it is 1 years old, younger than the Texas average of 44.4 years.

The most recent inspection reported to the Federal Highway Administration rates it in good condition with a lowest component rating of 7 out of 9. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

It carries about 155,355 vehicles a day, roughly 10% of them trucks, projected to reach 21,497 by 2042. The structure is 1,399 ft (426.4 m) long and 38 ft wide. If it were closed, the detour would be 1.2 mi (2 km).

CarriesSH 183 Eb-Sp 482NB
CrossesSH 183 & SP 482 SB
Location0.2 MI E of Loop 12
RouteState Highway 183
StateTexas
Coordinates32.83671, -96.90998
Functional classUrban Other Principal Arterial

Condition and inspection

Good

All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

ComponentRatingMeaning
Deck7 GoodSome minor problems.
Superstructure7 GoodSome minor problems.
Substructure8 Very GoodNo problems noted.
Last inspectionMay 2024
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourBridge not over waterway
Structural evaluation7: Better than present minimum criteria
Deck geometry2: Basically intolerable, requiring high priority of replacement
Approach roadway alignment8: Equal to present desirable criteria
Operating rating60 US tons
Inventory rating36 US tons

Structure

MaterialPrestressed Concrete
DeckConcrete, cast-in-place
Main spans12
Design loadHL 93
Structure length1,399 ft (426.4 m)
Longest span160 ft (48.8 m)
Deck width38 ft (11.6 m)
Roadway width36 ft (11 m)
Vertical clearance over deck17 ft (5.2 m)

Traffic and service

Average daily traffic155,355 (2022)
Projected traffic21,497 by 2042
Trucks10%
Lanes on structure3
Traffic directionOne-way traffic
CarriesHighway
CrossesHighway
Detour if closed1.2 mi (2 km)
TollOn a free road
National Highway SystemYes

Ownership and planned work

OwnerState Highway Agency
Maintained byState Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedNone recorded
Estimated improvement cost—
NavigationNot applicable (no waterway)

Frequently asked questions

When was SH 183 Eb-Sp 482NB over SH 183 & SP 482 SB built?

It was built in 2024, making it 1 years old in 2025.

What condition is SH 183 Eb-Sp 482NB over SH 183 & SP 482 SB in?

The National Bridge Inventory rates it in good condition. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted. The last reported inspection was in May 2024.

How much traffic does SH 183 Eb-Sp 482NB over SH 183 & SP 482 SB carry?

About 155,355 vehicles per day (2022 count), of which roughly 10% are trucks.

How long is SH 183 Eb-Sp 482NB over SH 183 & SP 482 SB?

The structure is 1,399 ft (426.4 m) long with a longest span of 160 ft (48.8 m) and a deck 38 ft wide.

Who owns SH 183 Eb-Sp 482NB over SH 183 & SP 482 SB?

It is owned by the State Highway Agency.