US Bridges

Graham St. over San Pedro Creek

Good

Bexar County, Texas · 0.1 MI W of S Flores ST · Structure no. 150150B14345002

Built
2022
3 years old
Condition
Good
inspected August 2023
Type
Box Beam or Girders - Multiple
Prestressed Concrete
Length
38 ft
1 main span
Daily traffic
540
2011 count
Owner
City
City or Municipal Highway Agency

About this bridge

Graham St. over San Pedro Creek is a prestressed concrete box beam or girders - multiple carrying Graham St. over San Pedro Creek in Bexar County, Texas. It was built in 2022, so it is 3 years old, younger than the Texas average of 44.4 years.

The most recent inspection reported to the Federal Highway Administration rates it in good condition with a lowest component rating of 8 out of 9. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

It carries about 540 vehicles a day, projected to reach 1 by 1900. The structure is 38 ft (11.6 m) long and 33 ft wide. If it were closed, the detour would be 1.2 mi (2 km).

CarriesGraham St.
CrossesSan Pedro Creek
Location0.1 MI W of S Flores ST
RouteCity Street 0
StateTexas
Coordinates29.42123, -98.49691
Functional classUrban Local

Condition and inspection

Good

All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted.

ComponentRatingMeaning
Deck8 Very GoodNo problems noted.
Superstructure8 Very GoodNo problems noted.
Substructure8 Very GoodNo problems noted.
Channel and channel protection8 Very GoodNo problems noted.
Last inspectionAugust 2023
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourScour evaluation has not been made
Structural evaluation6: Equal to present minimum criteria
Deck geometry4: Meets minimum tolerable limits to be left in place as is
Waterway adequacy7: Better than present minimum criteria
Approach roadway alignment8: Equal to present desirable criteria
Operating rating36 US tons
Inventory rating27 US tons

Structure

MaterialPrestressed Concrete
DeckConcrete, precast panels
Main spans1
Design loadUnknown
Structure length38 ft (11.6 m)
Longest span38 ft (11.6 m)
Deck width33 ft (10.2 m)
Roadway width22 ft (6.7 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic540 (2011)
Projected traffic1 by 1900
Trucks0%
Lanes on structure2
Traffic directionTwo-way traffic
CarriesHighway
CrossesWaterway
Detour if closed1.2 mi (2 km)
TollOn a free road
National Highway SystemNo

Ownership and planned work

OwnerCity or Municipal Highway Agency
Maintained byCity or Municipal Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedNone recorded
Estimated improvement cost—
NavigationNo navigation control on waterway

Frequently asked questions

When was Graham St. over San Pedro Creek built?

It was built in 2022, making it 3 years old in 2025.

What condition is Graham St. over San Pedro Creek in?

The National Bridge Inventory rates it in good condition. All primary components (deck, superstructure, substructure, or culvert) are rated 7 or higher. No significant problems were noted. The last reported inspection was in August 2023.

How much traffic does Graham St. over San Pedro Creek carry?

About 540 vehicles per day (2011 count).

How long is Graham St. over San Pedro Creek?

The structure is 38 ft (11.6 m) long with a longest span of 38 ft (11.6 m) and a deck 33 ft wide.

Who owns Graham St. over San Pedro Creek?

It is owned by the City or Municipal Highway Agency.