US Bridges

FAP 100 over SR 100 Ll / SR 96

FairPosted for load

Williamson County, Tennessee · 4.7 M SE JCT I40&SR96 · Structure no. 94SR0960002

Built
1957
68 years old, rebuilt 2001
Condition
Fair
inspected December 2024
Type
Box Beam or Girders - Single or Spread
Prestressed Concrete Continuous
Length
128 ft
3 main spans
Daily traffic
14,773
2021 count
Owner
State
State Highway Agency

About this bridge

FAP 100 over SR 100 Ll / SR 96 is a prestressed concrete continuous box beam or girders - single or spread carrying FAP 100 over SR 100 Ll / SR 96 in Williamson County, Tennessee. It was built in 1957 and reconstructed in 2001, so it is 68 years old, older than the Tennessee average of 47.4 years.

The most recent inspection reported to the Federal Highway Administration rates it in fair condition with a lowest component rating of 6 out of 9. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. Its operating status is: posted for load restriction.

It carries about 14,773 vehicles a day, roughly 9% of them trucks, projected to reach 24,496 by 2041. The structure is 128 ft (39 m) long and 40 ft wide.

CarriesFAP 100
CrossesSR 100 Ll / SR 96
Location4.7 M SE JCT I40&SR96
RouteState Highway 100
Coordinates35.98402, -87.1151
Functional classUrban Other Principal Arterial

Condition and inspection

Fair

The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

ComponentRatingMeaning
Deck7 GoodSome minor problems.
Superstructure7 GoodSome minor problems.
Substructure6 SatisfactoryStructural elements show some minor deterioration.
Last inspectionDecember 2024
Inspection intervalevery 24 months
Operating statusPosted for load restriction
ScourBridge not over waterway
Structural evaluation6: Equal to present minimum criteria
Deck geometry6: Equal to present minimum criteria
Approach roadway alignment8: Equal to present desirable criteria
Operating rating59.5 US tons
Inventory rating35.7 US tons

Structure

MaterialPrestressed Concrete Continuous
DeckConcrete, precast panels
Main spans3
Design loadHS 20
Structure length128 ft (39 m)
Longest span48 ft (14.6 m)
Deck width40 ft (12.2 m)
Roadway width37 ft (11.2 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic14,773 (2021)
Projected traffic24,496 by 2041
Trucks9%
Lanes on structure2
Traffic directionOne-way traffic
CarriesHighway
CrossesHighway
Detour if closed—
TollOn a free road
National Highway SystemYes

Ownership and planned work

OwnerState Highway Agency
Maintained byState Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedNone recorded
Estimated improvement cost—
NavigationNot applicable (no waterway)

Frequently asked questions

When was FAP 100 over SR 100 Ll / SR 96 built?

It was built in 1957, making it 68 years old in 2025. It was reconstructed in 2001.

What condition is FAP 100 over SR 100 Ll / SR 96 in?

The National Bridge Inventory rates it in fair condition. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. The last reported inspection was in December 2024.

How much traffic does FAP 100 over SR 100 Ll / SR 96 carry?

About 14,773 vehicles per day (2021 count), of which roughly 9% are trucks.

How long is FAP 100 over SR 100 Ll / SR 96?

The structure is 128 ft (39 m) long with a longest span of 48 ft (14.6 m) and a deck 40 ft wide.

Who owns FAP 100 over SR 100 Ll / SR 96?

It is owned by the State Highway Agency.