US Bridges

FAP 70 730216V over Southern Railway

Poor

Hawkins County, Tennessee · .4 M W of SR066 · Structure no. 37SR0700009

Built
1967
58 years old
Condition
Poor
inspected August 2024
Type
Stringer/Multi-beam or Girder
Prestressed Concrete Continuous
Length
121 ft
3 main spans
Daily traffic
3,196
2021 count
Owner
State
State Highway Agency

About this bridge

FAP 70 730216V over Southern Railway is a prestressed concrete continuous stringer/multi-beam or girder carrying FAP 70 730216V over Southern Railway in Hawkins County, Tennessee. It was built in 1967, so it is 58 years old, older than the Tennessee average of 47.4 years.

The most recent inspection reported to the Federal Highway Administration rates it in poor condition with a lowest component rating of 4 out of 9. The lowest-rated primary component is rated 4 or below, indicating advanced deterioration. Poor does not mean unsafe; such bridges are inspected more often and may carry load restrictions.

It carries about 3,196 vehicles a day, roughly 6% of them trucks, projected to reach 5,114 by 2042. The structure is 121 ft (36.9 m) long and 34 ft wide. If it were closed, the detour would be 47.2 mi (76 km).

CarriesFAP 70 730216V
CrossesSouthern Railway
Location.4 M W of SR066
RouteState Highway 70
Coordinates36.35198, -83.0108
Functional classRural Minor Arterial

Condition and inspection

Poor

The lowest-rated primary component is rated 4 or below, indicating advanced deterioration. Poor does not mean unsafe; such bridges are inspected more often and may carry load restrictions.

ComponentRatingMeaning
Deck5 FairAll primary structural elements are sound but may have minor section loss, cracking, spalling or scour.
Superstructure7 GoodSome minor problems.
Substructure4 PoorAdvanced section loss, deterioration, spalling or scour.
Last inspectionAugust 2024
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourBridge not over waterway
Structural evaluation4: Meets minimum tolerable limits to be left in place as is
Deck geometry3: Basically intolerable, requiring high priority of corrective action
Approach roadway alignment8: Equal to present desirable criteria
Operating rating35.7 US tons
Inventory rating27.4 US tons

Structure

MaterialPrestressed Concrete Continuous
DeckConcrete, cast-in-place
Main spans3
Design loadHS 20 + Mod
Structure length121 ft (36.9 m)
Longest span40 ft (12.2 m)
Deck width34 ft (10.4 m)
Roadway width28 ft (8.4 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic3,196 (2021)
Projected traffic5,114 by 2042
Trucks6%
Lanes on structure2
Traffic directionTwo-way traffic
CarriesHighway
CrossesRailroad
Detour if closed47.2 mi (76 km)
TollOn a free road
National Highway SystemNo

Ownership and planned work

OwnerState Highway Agency
Maintained byState Highway Agency
Historic statusHistorical significance not determinable at this time
Work proposedRehabilitation because of general structure deterioration or inadequate strength
Estimated improvement cost$1.1 million (2022 estimate)
NavigationNot applicable (no waterway)

Frequently asked questions

When was FAP 70 730216V over Southern Railway built?

It was built in 1967, making it 58 years old in 2025.

What condition is FAP 70 730216V over Southern Railway in?

The National Bridge Inventory rates it in poor condition. The lowest-rated primary component is rated 4 or below, indicating advanced deterioration. Poor does not mean unsafe; such bridges are inspected more often and may carry load restrictions. The last reported inspection was in August 2024.

How much traffic does FAP 70 730216V over Southern Railway carry?

About 3,196 vehicles per day (2021 count), of which roughly 6% are trucks.

How long is FAP 70 730216V over Southern Railway?

The structure is 121 ft (36.9 m) long with a longest span of 40 ft (12.2 m) and a deck 34 ft wide.

Who owns FAP 70 730216V over Southern Railway?

It is owned by the State Highway Agency.