US Bridges

SD044 over Draw

Fair

Pennington County, South Dakota · 0.7 SE of Farmingdale · Structure no. 000000052595389

Built
1964
61 years old
Condition
Fair
inspected June 2023
Type
Stringer/Multi-beam or Girder
Steel Continuous
Length
145 ft
3 main spans
Daily traffic
2,247
2024 count
Owner
State
State Highway Agency

About this bridge

SD044 over Draw is a steel continuous stringer/multi-beam or girder carrying SD044 over Draw in Pennington County, South Dakota. It was built in 1964, so it is 61 years old, older than the South Dakota average of 48.9 years.

The most recent inspection reported to the Federal Highway Administration rates it in fair condition with a lowest component rating of 6 out of 9. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

It carries about 2,247 vehicles a day, roughly 6% of them trucks, projected to reach 3,544 by 2044. The structure is 145 ft (44.2 m) long and 32 ft wide. If it were closed, the detour would be 11.8 mi (19 km).

CarriesSD044
CrossesDraw
Location0.7 SE of Farmingdale
RouteState Highway 44
Coordinates43.95626, -102.8694
Functional classRural Minor Arterial

Condition and inspection

Fair

The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

ComponentRatingMeaning
Deck7 GoodSome minor problems.
Superstructure6 SatisfactoryStructural elements show some minor deterioration.
Substructure6 SatisfactoryStructural elements show some minor deterioration.
Channel and channel protection6 SatisfactoryStructural elements show some minor deterioration.
Last inspectionJune 2023
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourFoundations stable; scour within limits of footing or piles
Structural evaluation6: Equal to present minimum criteria
Deck geometry4: Meets minimum tolerable limits to be left in place as is
Waterway adequacy9: Superior to present desirable criteria
Approach roadway alignment8: Equal to present desirable criteria
Operating rating50.8 US tons
Inventory rating30.4 US tons

Structure

MaterialSteel Continuous
DeckConcrete, cast-in-place
Main spans3
Design loadHS 20
Structure length145 ft (44.2 m)
Longest span55 ft (16.8 m)
Deck width32 ft (9.8 m)
Roadway width30 ft (9.1 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic2,247 (2024)
Projected traffic3,544 by 2044
Trucks6%
Lanes on structure2
Traffic directionTwo-way traffic
CarriesHighway
CrossesWaterway
Detour if closed11.8 mi (19 km)
TollOn a free road
National Highway SystemNo

Ownership and planned work

OwnerState Highway Agency
Maintained byState Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedNone recorded
Estimated improvement cost—
NavigationNo navigation control on waterway

Frequently asked questions

When was SD044 over Draw built?

It was built in 1964, making it 61 years old in 2025.

What condition is SD044 over Draw in?

The National Bridge Inventory rates it in fair condition. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. The last reported inspection was in June 2023.

How much traffic does SD044 over Draw carry?

About 2,247 vehicles per day (2024 count), of which roughly 6% are trucks.

How long is SD044 over Draw?

The structure is 145 ft (44.2 m) long with a longest span of 55 ft (16.8 m) and a deck 32 ft wide.

Who owns SD044 over Draw?

It is owned by the State Highway Agency.