US Bridges

SR 0981 over Branch of Barron Run

Fair

Westmoreland County, Pennsylvania · South Huntingdon Township · Structure no. 000000000036297

Built
1928
97 years old, rebuilt 2007
Condition
Fair
inspected July 2023
Type
Tee Beam
Concrete
Length
24 ft
1 main span
Daily traffic
1,241
2024 count
Owner
State
State Highway Agency

About this bridge

SR 0981 over Branch of Barron Run is a concrete tee beam carrying SR 0981 over Branch of Barron Run in Westmoreland County, Pennsylvania. It was built in 1928 and reconstructed in 2007, so it is 97 years old, older than the Pennsylvania average of 54.8 years.

The most recent inspection reported to the Federal Highway Administration rates it in fair condition with a lowest component rating of 5 out of 9. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

It carries about 1,241 vehicles a day, roughly 12% of them trucks, projected to reach 1,722 by 2032. The structure is 24 ft (7.3 m) long and 26 ft wide. If it were closed, the detour would be 24.2 mi (39 km).

CarriesSR 0981
CrossesBranch of Barron Run
LocationSouth Huntingdon Township
RouteState Highway 981
Coordinates40.15373, -79.69144
Functional classRural Major Collector

Condition and inspection

Fair

The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

ComponentRatingMeaning
Deck5 FairAll primary structural elements are sound but may have minor section loss, cracking, spalling or scour.
Superstructure5 FairAll primary structural elements are sound but may have minor section loss, cracking, spalling or scour.
Substructure5 FairAll primary structural elements are sound but may have minor section loss, cracking, spalling or scour.
Channel and channel protection4 PoorAdvanced section loss, deterioration, spalling or scour.
Last inspectionJuly 2023
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourFoundations stable; scour above top of footing
Structural evaluation5: Somewhat better than minimum adequacy to tolerate being left in place as is
Deck geometry4: Meets minimum tolerable limits to be left in place as is
Waterway adequacy9: Superior to present desirable criteria
Approach roadway alignment7: Better than present minimum criteria
Operating rating70 US tons
Inventory rating46 US tons

Structure

Structure typeTee Beam
MaterialConcrete
DeckConcrete, cast-in-place
Main spans1
Design loadHS 25 or greater
Structure length24 ft (7.3 m)
Longest span22 ft (6.7 m)
Deck width26 ft (7.8 m)
Roadway width24 ft (7.4 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic1,241 (2024)
Projected traffic1,722 by 2032
Trucks12%
Lanes on structure2
Traffic directionTwo-way traffic
CarriesHighway
CrossesWaterway
Detour if closed24.2 mi (39 km)
TollOn a free road
National Highway SystemNo

Ownership and planned work

OwnerState Highway Agency
Maintained byState Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedReplacement because of substandard load-carrying capacity or roadway geometry
Estimated improvement cost$258,000
NavigationNo navigation control on waterway

Frequently asked questions

When was SR 0981 over Branch of Barron Run built?

It was built in 1928, making it 97 years old in 2025. It was reconstructed in 2007.

What condition is SR 0981 over Branch of Barron Run in?

The National Bridge Inventory rates it in fair condition. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. The last reported inspection was in July 2023.

How much traffic does SR 0981 over Branch of Barron Run carry?

About 1,241 vehicles per day (2024 count), of which roughly 12% are trucks.

How long is SR 0981 over Branch of Barron Run?

The structure is 24 ft (7.3 m) long with a longest span of 22 ft (6.7 m) and a deck 26 ft wide.

Who owns SR 0981 over Branch of Barron Run?

It is owned by the State Highway Agency.