US Bridges

SR 4003 over Bradley Run

Fair

Potter County, Pennsylvania · 3 MI S Clara · Structure no. 000000000046728

Built
2011
14 years old
Condition
Fair
inspected August 2023
Type
Stringer/Multi-beam or Girder
Steel
Length
27 ft
1 main span
Daily traffic
68
2024 count
Owner
State
State Highway Agency

About this bridge

SR 4003 over Bradley Run is a steel stringer/multi-beam or girder carrying SR 4003 over Bradley Run in Potter County, Pennsylvania. It was built in 2011, so it is 14 years old, younger than the Pennsylvania average of 54.8 years.

The most recent inspection reported to the Federal Highway Administration rates it in fair condition with a lowest component rating of 6 out of 9. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

It carries about 68 vehicles a day, roughly 10% of them trucks, projected to reach 168 by 2043. The structure is 27 ft (8.2 m) long and 19 ft wide. If it were closed, the detour would be 23 mi (37 km).

CarriesSR 4003
CrossesBradley Run
Location3 MI S Clara
RouteState Highway 0
Coordinates41.88105, -78.11502
Functional classRural Local

Condition and inspection

Fair

The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.

ComponentRatingMeaning
Deck6 SatisfactoryStructural elements show some minor deterioration.
Superstructure7 GoodSome minor problems.
Substructure8 Very GoodNo problems noted.
Channel and channel protection7 GoodSome minor problems.
Last inspectionAugust 2023
Inspection intervalevery 24 months
Operating statusOpen, no restriction
ScourFoundations stable; scour above top of footing
Structural evaluation7: Better than present minimum criteria
Deck geometry3: Basically intolerable, requiring high priority of corrective action
Waterway adequacy5: Somewhat better than minimum adequacy to tolerate being left in place as is
Approach roadway alignment8: Equal to present desirable criteria
Operating rating94 US tons
Inventory rating56 US tons

Structure

MaterialSteel
DeckWood or timber
Main spans1
Design loadHS 20
Structure length27 ft (8.2 m)
Longest span25 ft (7.6 m)
Deck width19 ft (5.7 m)
Roadway width17 ft (5.1 m)
Vertical clearance over deckUnrestricted

Traffic and service

Average daily traffic68 (2024)
Projected traffic168 by 2043
Trucks10%
Lanes on structure1
Traffic directionOne-lane bridge for two-way traffic
CarriesHighway
CrossesWaterway
Detour if closed23 mi (37 km)
TollOn a free road
National Highway SystemNo

Ownership and planned work

OwnerState Highway Agency
Maintained byState Highway Agency
Historic statusNot eligible for the National Register of Historic Places
Work proposedNone recorded
Estimated improvement cost—
NavigationNo navigation control on waterway

Frequently asked questions

When was SR 4003 over Bradley Run built?

It was built in 2011, making it 14 years old in 2025.

What condition is SR 4003 over Bradley Run in?

The National Bridge Inventory rates it in fair condition. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. The last reported inspection was in August 2023.

How much traffic does SR 4003 over Bradley Run carry?

About 68 vehicles per day (2024 count), of which roughly 10% are trucks.

How long is SR 4003 over Bradley Run?

The structure is 27 ft (8.2 m) long with a longest span of 25 ft (7.6 m) and a deck 19 ft wide.

Who owns SR 4003 over Bradley Run?

It is owned by the State Highway Agency.