SR 0309 TR 309 over TR 11 Wyoming Avenue
FairLuzerne County, Pennsylvania · Kingston Boro over TR 11 · Structure no. 000000000023882
- Built
- 1980
- 45 years old
- Condition
- Fair
- inspected September 2024
- Type
- Stringer/Multi-beam or Girder
- Prestressed Concrete
- Length
- 165 ft
- 3 main spans
- Daily traffic
- 35,094
- 2024 count
- Owner
- State
- State Highway Agency
About this bridge
SR 0309 TR 309 over TR 11 Wyoming Avenue is a prestressed concrete stringer/multi-beam or girder carrying SR 0309 TR 309 over TR 11 Wyoming Avenue in Luzerne County, Pennsylvania. It was built in 1980, so it is 45 years old, younger than the Pennsylvania average of 54.8 years.
The most recent inspection reported to the Federal Highway Administration rates it in fair condition with a lowest component rating of 6 out of 9. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.
It carries about 35,094 vehicles a day, roughly 6% of them trucks, projected to reach 45,364 by 2032. The structure is 165 ft (50.3 m) long and 86 ft wide. If it were closed, the detour would be 3.1 mi (5 km).
Location
Open in Google MapsCondition and inspection
The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound.
| Component | Rating | Meaning |
|---|---|---|
| Deck | 7 Good | Some minor problems. |
| Superstructure | 6 Satisfactory | Structural elements show some minor deterioration. |
| Substructure | 7 Good | Some minor problems. |
Structure
Traffic and service
Ownership and planned work
Frequently asked questions
When was SR 0309 TR 309 over TR 11 Wyoming Avenue built?
It was built in 1980, making it 45 years old in 2025.
What condition is SR 0309 TR 309 over TR 11 Wyoming Avenue in?
The National Bridge Inventory rates it in fair condition. The lowest-rated primary component is rated 5 or 6. Minor deterioration is present but the structure is sound. The last reported inspection was in September 2024.
How much traffic does SR 0309 TR 309 over TR 11 Wyoming Avenue carry?
About 35,094 vehicles per day (2024 count), of which roughly 6% are trucks.
How long is SR 0309 TR 309 over TR 11 Wyoming Avenue?
The structure is 165 ft (50.3 m) long with a longest span of 97 ft (29.6 m) and a deck 86 ft wide.
Who owns SR 0309 TR 309 over TR 11 Wyoming Avenue?
It is owned by the State Highway Agency.