SR 0690 TR 690 over Roaring Brook
PoorLackawanna County, Pennsylvania · Moscow Boro .2M E SR 2005 · Structure no. 000000000020662
- Built
- 1961
- 64 years old
- Condition
- Poor
- inspected July 2024
- Type
- Box Beam or Girders - Multiple
- Prestressed Concrete
- Length
- 66 ft
- 1 main span
- Daily traffic
- 2,434
- 2024 count
- Owner
- State
- State Highway Agency
About this bridge
SR 0690 TR 690 over Roaring Brook is a prestressed concrete box beam or girders - multiple carrying SR 0690 TR 690 over Roaring Brook in Lackawanna County, Pennsylvania. It was built in 1961, so it is 64 years old, older than the Pennsylvania average of 54.8 years.
The most recent inspection reported to the Federal Highway Administration rates it in poor condition with a lowest component rating of 4 out of 9. The lowest-rated primary component is rated 4 or below, indicating advanced deterioration. Poor does not mean unsafe; such bridges are inspected more often and may carry load restrictions.
It carries about 2,434 vehicles a day, roughly 3% of them trucks, projected to reach 3,396 by 2032. The structure is 66 ft (20.1 m) long and 39 ft wide. If it were closed, the detour would be 1.9 mi (3 km).
Location
Open in Google MapsCondition and inspection
The lowest-rated primary component is rated 4 or below, indicating advanced deterioration. Poor does not mean unsafe; such bridges are inspected more often and may carry load restrictions.
| Component | Rating | Meaning |
|---|---|---|
| Deck | 4 Poor | Advanced section loss, deterioration, spalling or scour. |
| Superstructure | 4 Poor | Advanced section loss, deterioration, spalling or scour. |
| Substructure | 6 Satisfactory | Structural elements show some minor deterioration. |
| Channel and channel protection | 6 Satisfactory | Structural elements show some minor deterioration. |
Structure
Traffic and service
Ownership and planned work
Frequently asked questions
When was SR 0690 TR 690 over Roaring Brook built?
It was built in 1961, making it 64 years old in 2025.
What condition is SR 0690 TR 690 over Roaring Brook in?
The National Bridge Inventory rates it in poor condition. The lowest-rated primary component is rated 4 or below, indicating advanced deterioration. Poor does not mean unsafe; such bridges are inspected more often and may carry load restrictions. The last reported inspection was in July 2024.
How much traffic does SR 0690 TR 690 over Roaring Brook carry?
About 2,434 vehicles per day (2024 count), of which roughly 3% are trucks.
How long is SR 0690 TR 690 over Roaring Brook?
The structure is 66 ft (20.1 m) long with a longest span of 64 ft (19.5 m) and a deck 39 ft wide.
Who owns SR 0690 TR 690 over Roaring Brook?
It is owned by the State Highway Agency.