SR8006(I 70 0FFRP) over Mckees Run
PoorFulton County, Pennsylvania · Amaranth Exit I-70 · Structure no. 000000000018003
- Built
- 1932
- 93 years old, rebuilt 2010
- Condition
- Poor
- inspected February 2024
- Type
- Tee Beam
- Concrete
- Length
- 27 ft
- 1 main span
- Daily traffic
- 87
- 2024 count
- Owner
- State
- State Highway Agency
About this bridge
SR8006(I 70 0FFRP) over Mckees Run is a concrete tee beam carrying SR8006(I 70 0FFRP) over Mckees Run in Fulton County, Pennsylvania. It was built in 1932 and reconstructed in 2010, so it is 93 years old, older than the Pennsylvania average of 54.8 years.
The most recent inspection reported to the Federal Highway Administration rates it in poor condition with a lowest component rating of 4 out of 9. The lowest-rated primary component is rated 4 or below, indicating advanced deterioration. Poor does not mean unsafe; such bridges are inspected more often and may carry load restrictions.
It carries about 87 vehicles a day, roughly 13% of them trucks, projected to reach 60 by 2032. The structure is 27 ft (8.2 m) long and 26 ft wide. If it were closed, the detour would be 1.2 mi (2 km).
Location
Open in Google MapsCondition and inspection
The lowest-rated primary component is rated 4 or below, indicating advanced deterioration. Poor does not mean unsafe; such bridges are inspected more often and may carry load restrictions.
| Component | Rating | Meaning |
|---|---|---|
| Deck | 5 Fair | All primary structural elements are sound but may have minor section loss, cracking, spalling or scour. |
| Superstructure | 4 Poor | Advanced section loss, deterioration, spalling or scour. |
| Substructure | 5 Fair | All primary structural elements are sound but may have minor section loss, cracking, spalling or scour. |
| Channel and channel protection | 5 Fair | All primary structural elements are sound but may have minor section loss, cracking, spalling or scour. |
Structure
Traffic and service
Ownership and planned work
Frequently asked questions
When was SR8006(I 70 0FFRP) over Mckees Run built?
It was built in 1932, making it 93 years old in 2025. It was reconstructed in 2010.
What condition is SR8006(I 70 0FFRP) over Mckees Run in?
The National Bridge Inventory rates it in poor condition. The lowest-rated primary component is rated 4 or below, indicating advanced deterioration. Poor does not mean unsafe; such bridges are inspected more often and may carry load restrictions. The last reported inspection was in February 2024.
How much traffic does SR8006(I 70 0FFRP) over Mckees Run carry?
About 87 vehicles per day (2024 count), of which roughly 13% are trucks.
How long is SR8006(I 70 0FFRP) over Mckees Run?
The structure is 27 ft (8.2 m) long with a longest span of 26 ft (7.9 m) and a deck 26 ft wide.
Who owns SR8006(I 70 0FFRP) over Mckees Run?
It is owned by the State Highway Agency.